General Layout
PAW-TD20C1E5-UK
PAW-TD30C1E5-UK
PAW-TD30C1E5HI-UK
No. Key
1
Return HP 3/4" BSP (Flow Boiler 3/4" BSP)
2
Flow HP 3/4" BSP (Return Boiler 3/4" BSP)
3
Pressure Reducing Valve Multibloc (2.1 bar) includes Item 4
4
Expansion Relief Valve (8 bar)
5
Temperature and Pressure Relief Valve
6
Tundish
7
Immersion Heater
8
Immersion heater Control Thermostat
9
Cylinder Thermostat w/safety cut-out
10 Cold Water Inlet - 3/4" BSP / Ø22
11
Hot Water Outlet -3/4" BSP
12 Elbow / Drain Cock
13 Discharge Pipe (Not supplied)
4
14 Motorised Valve (Not factory fitted)
15 Expansion Vessel
16 Hot Water Circulation 3/4" BSP
T ( 1 : 6 )
6
D
Y
C
B
679
Power supply/
Sensor cable
inlet
Thermistor housing
A
Power supply/
Thermistor cable
duct
A-A
A
10
15
P/N
3
4
92020
6
13
72080
9
80317
2
80345
8
7
16
3
1
12
10
5
HW outlet
P&T valve 1/2"
Cylinder Thermostat
w/Safety Cut-Out
and Sensor pocket
3
Flow
" BSP female
4
1265 - 3 10
+
3
HWC
" BSP female
4
Immersion Heater w/
Thermostat & Safety
Cut-out
866
Housing for
Sensor probe
3
Return
4
3
CW inlet
Power supply and Sensor cable inlet
266
5
2
4
3
" BSP female
4
" BSP female
" BSP female
4
11
1
Power supply/
Thermistor cable
inlet
A
3

Hide quick links: