Performance Characteristic Tables

3
3
32
Performance Characteristic Tables
The following tables refer to the heating up of the water without reheating and can not be com-
part with Tapping profile data tables.
How to read the following tables:
3.1 Capacity table PAW-VP1000LDHW (10 °C)
City water inlet temp:
Outdoor unit type:
Tank type:
Ambient
Water temp
temperature
WB
Set temp
45°C
+7°C
50°C
55°C
The example table refers to a supply water temperature of 10°C.
The water in the tank is heated from 10°C to 50°C at an ambient temperature of 7°C. The heat-
ing phase takes 3:23:47h.
(Without tapping)
In practice, the cycle described above is valid during commissioning. If system design in ac-
cordance with local conditions, then in the rarest cases so much water is tapped that the tank is
completely emptied and filled with fresh water.
Temperature layering
The table on the left side shows
Tapping amount 50°C*
the total water volume for each
PAW-VP1000LDHW
temperature layer within the tank.
[°C]
[ltr.]
The indication Tapping amount
>65°C
0.00
50°C refers to the compressor
>60°C
212.75
cut-off temperature.
>55°C
44.62
>50°C
227.30
>45°C
115.43
>40°C
94.09
10 °C
U-250PE2E8A
PAW-VP1000LDHW
Time
Heating Capacity Power Input
[h:m:s]
[kWh]
2:41:04
38.27
3:23:47
44.34
4:08:34
48.38
212.75 liters of water can
be tapped at temperatures
above 60°C.
44.62 liters of water can be
tapped at temperatures below
60°C and above 55°C.
PAW-VP•LDHW - Technical Manual – 2020-07
COP
[kWh]
[kWh / kWh]
10.71
3.57
13.55
3.27
16.53
2.93
<60°C –
<55°C –
<50°C –
<45°C –
<40°C –
<60°C –
212.75 ltr.
44.62 ltr.
227.30 ltr.
115.43 ltr.
94.09 ltr.
238.81 ltr.

Advertisement