Introduction - Crown ECT-6 Installation And Operation Manual

Self-generating steam jacketed counter tilting kettles
Table of Contents

Advertisement

Self-Generating Steam Jacketed Counter Tilting Kettles

Introduction

Description
Models ECT-6 (6 gallon capacity) and ECT-10 (10 gallon capacity) and ECT-12 (12 gallon capacity) electrically
powered, self-contained, countertop, tilting kettles. Each model has a jacket of double-wall construction forming
a sealed reservoir around the lower two-thirds of the kettle. The reservoir is charged with distilled water and
anti-freeze solution. Kettles are equipped with a removable electric heating element and controls, including a low
water cutoff device for protection of the heating element. All models are of identical construction, except for kettle
size and element heating capacity.
Basic Function
Self-contained kettles operate by generating steam in the kettle reservoir. The sequence of operation is as follows:
1. Operator turns the power switch to the ON position and sets the temperature control dial to the desired
setting from 1 to 10.
2. Control circuit is normally completed to the temperature controller if the following conditions exist:
a) Water level in the kettle reservoir is adequate to prevent circuit interruption by the low water cut off
device. An activated cutoff is indicated by the amber low water light turning on, and the heating element
shut off.
b) Kettle is in vertical position with circuit completed through the tilt interlock switch.
3. Thermostat control contacts close to energize contactor coils.
4. Power is supplied to the elements through closed power contactors.
5. As the temperature of water rises in the kettle reservoir, increase in steam pressure is indicated on the
pressure gauge.
6. When the temperature of steam in the reservoir reaches the setting of the temperature control dial, the
temperature controller opens to break the contacts and shuts off the heating element. The heating elements
will cycle on and off as required to maintain temperature setting.
INSTALLATION & OPERATION MANUAL 10132 REV 2 (08/22)
Introduction
5
PAGE
OF24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ect-10Ect-12

Table of Contents