The MV1000S dust collector is a rugged, powerful
unit that is sure to meet your expectations for dust
control.
See technical data below:
Voltage
Power
Air pressure
Airflow
Hose
Weight
Dimension
Plastic dust bag 22x32 in (550x800 mm) (LDPE)
Noise

TROUBLESHOOTING

PROBLEM
Possible Reason(s)/Solution(s)
MOTOR DOES NO START
No power, cable or switch defective
MOTOR RUNS BUT NO SUCTION
Hose not connected or blocked
MOTOR RUNS W/ POOR SUCTION
Hose damaged
Filter blocked
Top cover loose
DUST BLOWS FROM MOTOR
Filter loose or defective
ABNORMAL NOISE
Check motor(s)
6
220 V / 60 Hz - Single phase
4050 W (5.3 HP)
3000 mm Aq
330 c.f.m
2" (50 mm) Dia.
175lbs (80kg) (net)
27x27x62 in (67x67x155 cm) (LxWxH)
75 dB

SETUP

Connect hoses.
If using a separator:
Connect one end of the Short Vacuum Hose to the
inlet of the MaxiVac. Connect the other end of the
short hose to the outlet of the separator.
Connect one end of the Long Vacuum Hose to the
inlet of the separator. Connect the other end of the
long hose to the vacuum hookup on the SMITH
machine.
If not using a separator:
Connect one end of the Long Vacuum Hose to the
inlet of the MaxiVac. Connect the other end of the
long hose to the vacuum hookup on the machine.
NOTE: Use the Y-Connector to connect 2 hoses to the
vacuum or separator, if desired.