Page 4
FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
Page 5
Use only with a mounting accessory recommended by Vicon, or sold with the video product. Any mounting of the video product should follow Vicon’s instructions, and a mounting accessory recommended by Vicon should be used.
Page 6
Vicon or that have the same characteristics electric light or power circuits, or where it can fall into such as the original part.
CONTENTS Important Safeguards Unpacking …………………………………………………………………………. Service ………………………………………………………………………….. Description ………………………………………………………………………….. Installation ………………………………………………………………………….. Connections ………………………………………………………………………….. Programming ……………………………………………………………….……….. Time/Date ………………………………………………………………………….. ….. 5.1.1 Date Format ..………………………………………………………………………..4 5.1.2 Date Set………………………………………………………………………….. ……. 5.1.3 Time Format ………………………………………………………………………….. 5.1.4 Time Set ………………………………………………………………………….. …… Camera Titles …………………………………………………………………….….. Dwell Setup …………………………………………………………………………..
Description The V5160MUX Digital Color Multiplexer provides on-screen display of sixteen camera inputs combined with numerous additional functions. The image display is updated at the field rate of 60 field/sec. In addition to multi - screen displays or playback on a single monitor, multiplex recording on a VCR of up to 16 camera images is possible with this duplex multiplexer as well.
Installation Connections camera 16 DC 12V Power camera 2 Adapter Alarm Out camera 1 Alarm In Looping (Automatic Termination) RS232 Connector AC-IN RS485 Connector Trig In/Out Time Lapse VCR Spot Monitor Output Monitor Output Programming Table 1 Key Functions Key label Operating Function Programming Function Selects to display or delete Title on monitor...
All programming is done with the front panel keys. There are 21 keys on the front panel. The keys named MENU, FREEZE/+, ZOOM/-, △, SPOT/▽, SEQ/◁, CHANGE/▷, and SHIFT/ENTER are used in programming unit. The TITLE, VCR, and ALARM keys are not used in programming the unit. Functions of each key on the front panel are described in Table 1.
Alphabet (26 letters), Number (0~9), Special Characters ( [.],[,],[:],[+],[-],[*],[/],[(),[]],[?],[ ]). Press the MENU key to exit the menu. Note: To retain all titling (camera and alarm), the tape must be played back on the same V5160MUX it was recorded on.
ALARM SETUP (1) ALARM TITLES (2) ALARM ATTRIBUTE SETUP (3) VD LOSS ALARM SETUP (4) DWELL TIME = 60 SEC (5) BUZZER OUT = ON (6) RELAY OUT = ON (7) TRIG OUT = LOW 5.4.1 Alarm Titles You can select an Alarm title for each channel. Select ALARM TITLES and press the ENTER key.
5.4.3 VD Loss Alarm Setup The VIDEO LOSS ALARM function enables you to define if an alarm is generated when any of the video inputs is lost/not detected. Select VD LOSS ALARM SETUP and press the ENTER key. The following menu is displayed: VD LOSS ALARM SETUP CAMERA 01 = ON CAMERA 16 = ON...
RECORD SETUP (1) FIELD DELAY : 002 FIELD (2) REC MODE : FRAME REC(R/T) (3) ALM REC : NO CHANGE (4) ALM SPEED : FOLLOW (5) VCR INPUT : CVBS (6) ZONE SETUP (7) HOLIDAY SETUP (8) RECORD CAMERA SETUP 5.5.1 Field Delay Setup Select FIELD DELAY from the RECORD SETUP screen.
5.5.6 Zone Setup Select ZONE SETUP to set the recording time zone of each channel. Press ENTER key. The following menu is displayed. ZONE SETUP REC ZONE A = 10:00 – 13:00 REC ZONE B = 14:00 – 19:00 REC ZONE C = 11:00 – 18:00 REC ZONE D = 20:00 –...
RECORD CAMERA SETUP WEEKDAY WEEKEND CAMERA 01 = ALWAYS ALWAYS CAMERA 02 = ALWAYS ALWAYS CAMERA 03 = ALWAYS ALWAYS CAMERA 16 = ALWAYS ALWAYS Press the △ and ▽ key to select camera number. Press the ◁ and ▷ key to select weekday or weekend. Press (+) and (-) keys to select options: Options for WEEKDAY are : ALWAYS, ZONE A,B, ZONE A, ZONE B, SKIP Options for WEEKEND are : ALWAYS, ZONE C,D, ZONE C, ZONE D, SKIP...
Spot Monitor Setup Select SPOT MONITOR SETUP on MAIN MENU. Press the ENTER key. The following will be displayed: SPOT MONITOR SETUP (1) DWELL SETUP (2) TIME DISPLAY : ON (3) TITLE DISPLAY : ON (4) DISPLAY POSIT : BOTTOM 5.7.1 Spot Dwell Setup Select DWELL SETUP from the SPOT MONITOR SETUP screen.
5.9.2 Password Setup Select PASSWORD SETUP on the SYSTEM SETUP menu and press (+) or (-) key to toggle the options: DISABLE, ENABLE PASSWORD SETUP PASSWORD : DISABLE NEW PASSWORD: _ _ _ _ To enable a password, select “ENABLE ”. Select NEW PASSWORD and press the ENTER key.
LAPSE. This setting does not recognize Video Loss as an alarm condition. REC OUT Trigger Operation Mode When an alarm occurs, this signals the VCR to record. Trigger connection on rear panel of V5160MUX: Alarm In / Out Pin No.
7.1 Computer Remote Control The V5160MUX uses a very simple command set, each command consisting of three characters. The first character in all cases is the slash or virgule (/). The unit looks only for a three -character command, with an initial slash.
Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.