MCK-1094
February 2008
F180 Series Excess Flow Valves for
Compressed Air Service
TYPE F186
!
Failure to follow these instructions or to
properly install and maintain this
equipment could result in property
damage and personal injury or death.
Fisher
equipment must be installed,
®
operated, and maintained in accordance
with federal, state, and local codes and
Fisher instructions.
Only personnel trained in the proper
procedures, codes, standards, and
regulations of the applicable industries
should install and service this equipment.
R
Figure 1. F180 Series Excess Flow Valves
WARNING
www.emersonprocess.com/regulators/lp
TYPE F187
A break or leak downstream of an
excess flow valve that does not allow a
flow equal to the valve flow rating will
not actuate the excess flow valve and
could result in property damage or
personal injury from a whipping hose or
high volume discharge of air. For this
reason the operator must be familiar
with the system shutoff valves and close
the system if an emergency occurs.
Introduction
Scope of Manual
This instruction manual covers installation and
maintenance for F180 Series excess flow valves used
on compressed air service.
F180 Series
TYPE F188
WARNING
!

Advertisement

loading

Summary of Contents for Emerson FISHER F180 Series

  • Page 1 F180 Series Instruction Manual MCK-1094 February 2008 F180 Series Excess Flow Valves for Compressed Air Service TYPE F186 TYPE F187 TYPE F188 Figure 1. F180 Series Excess Flow Valves WARNING WARNING Failure to follow these instructions or to A break or leak downstream of an properly install and maintain this excess flow valve that does not allow a equipment could result in property...
  • Page 2 F180 Series Specifications CLOSING FLOW, CLOSING FLOW INLET OUTLET AIR SCFM DIFFERENTIAL BODY LENGTH, WRENCH HEX, TYPE CONNECTION, CONNECTION, MATERIAL (meters /min) AT PRESSURE, INCHES (cm) INCHES (cm) INCHES INCHES 100 PSIG PSIG (bar) (6,9 bar) INLET PRESSURE F186-06-1 3/4 MNPT 3/4 FNPT Brass 171 (4,8)
  • Page 3 F180 Series Maintenance components in the piping system create restrictions which reduce the flow rating to less than that of the excess flow valve rating, the valve will not give excess Excess flow valves are non-repairable. Replace flow protection, and additional excess flow valves must non-functioning valves.
  • Page 4 F180 Series Fisher and Fisher Regulators are marks owned by Fisher Controls International, LLC. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability.