4 Assembly and Operation

4.1 Assembly Instructions
• Make certain the fi tting is suitable for the relevant ap-
plication. The fi tting must be suitable for the operating
conditions of the pipeline system (medium, concentra-
tion, temperature and pressure) as well as the relevant
ambient conditions.
• Check the fi tting for transport damage before installing
it. If the fi tting is damaged do not install it.
• The planner, the construction company or operating
company are responsible for the positioning and instal-
lation of the fi tting. Planning and installation errors can
adversely affect the reliable functionality of the fi tting
and may represent a signifi cant potential for hazard.
• After the fi tting is installed perform a tightness and
function check.
4.2 Tools Required
The tools required for installation and assembly are not
included with delivery.
4.3 Connect Makro Filter
• The fi tting must be connected to the pipeline so it is
free of mechanical stress.
• The Filter has a female thread (ISO, DIN, ANSI) and/or
a tube connections and can be connected with various
connecting elements of the emtechnik system.
Cylindrical thread
Sealing is provided by a sealing collar for
Cylindrical threads (G, M or UNF).
A version with an O-ring is also possible.
Sealing Collar
O-Ring
• Each thread must always be connected with the same
thread type.
• If a plastic fi tting is used in combination with a metal-
lic male fi tting, additional sealing with Tefl on® tape is
recommended.
EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany
info@em-technik.com
4.4 Torque Chart
Plastic
PVDF
PP
4.5 Fastening Options
For the Filters are no fastening options intended.
5 Commissioning
5.1 Precondition for Commissioning
• Protect against leaks: Take protective measures
against exceeding the maximum permitted pressure
due to possible pressure surges.
• Check the tightness and function of the fi tting.
• In new systems and after repairs, fl ush the line system
to remove foreign materials.

6 Maintenance

• When used as designated, the fi tting is practically
wear-free and generally requires no maintenance.
• The operating company must perform regular visual
inspections of the fi tting according to the operating
conditions to prevent leaks and damage.
Conical thread
7 Disposal
Sealing is provided
• When disposing of the fi tting and packaging, comply
by the thread itself
with the relevant disposal requirements and environ-
for Conical threads
mental protection regulations.
(NPT).
• When disposing of fi ttings, pay careful attention to any
Thread
residues of toxic or corrosive media.

8 Return Delivery

Do not return before consulting with emtechnik.
1. Please consult with emtechnik.
2. Empty the fi tting properly.
3. Rinse and clean the fi tting thoroughly, especially if the
media is being conveyed are harmful, explosive, hot,
or hazardous in some other way.
4. For fi ttings that have been operated with aggressive,
corrosive, combustible, toxic or water polluting media,
a completely fi lled in clearance certifi cate must always
be included.
Thread
G 1/8"
G 1/4"
G 3/8"
1.0–2.0
5.0
5.0–7.0
1.0–1.5
2.5
5.0–6.0
www.em-technik.com
G 1/2"
G 3/4"
10.0
15.0
5.0
10.0
5