Hansen Technologies HSC4H-N10K Specifications, Applications, Service Instructions & Parts page 2

Gas detection sensors, monitors & alert systems
Table of Contents

Advertisement

SELECTING GAS SENSOR TYPES
Hansen Gas Sensors are available in several types of
enclosures to match the environmental and operating
conditions.
Standard Gas Sensor
For operating temperatures down to
0ºF (-17ºC). NEMA4 (IP65) watertight
e n c l o s u r e . M o u n t a b l e i n d o o r s o r
outdoors. Enclosure is ABS material
with a gasketed cover; single ½˝ conduit
knockout is provided.
Harsh Environment Gas Sensor
For oper ating temper atur e s down
to -40ºF (-40ºC) for wet/humid areas.
M o u n t a b l e i n d o o r s o r o u t d o o r s .
Enclosure is NEMA4 (IP65) ABS material;
conduit connection must be vaporproof.
Extreme Environment Gas Sensor
For operating temperatures down to
-60ºF (-51ºC). Features a stainless steel
metal enclosure and equipped with
an integral heater and thermostat for
low temperature operation. Mountable
indoor s or outdoor s. Enclosure is
NEMA4X (IP65); conduit connection
must be vaporproof.
Note: Auxilliary power required when
used with Hansen monitors HLM2 and
HLM6 and Gas Alert System.
Vent Line Gas Sensor
For operating temperatures down to
-40ºF (-40ºC). Mountable indoors or
outdoors. Enclosure is NEMA4 (IP65)
ABS material. Gas sensing element is
in a separate carbon steel housing with
an 1˝ NPT threaded connection; cable
is 10 feet (3 meters).
Explosion Proof Gas Sensor
For oper ating temper atur e s down
to -40ºF (-40ºC). Mountable indoors
or outdoor s . Enclosur e is NEM A7
Aluminum. Used where regulations and
codes specify; consult factory with
specific requirements. Class I, Div II,
Group C and D.
Basic Gas Sensor
For operating temperatures down to
32ºF (0ºC). For commercial applications
such as supermarket refrigeration
systems and air conditioning chillers.
Enclosure is NEMA1 (IP30) ABS material
for indoor installations. Low voltage
cable wiring only.
A100g
JULY 2017
PORTABLE GAS DETECTION UNIT
Portable Gas Detection unit includes
the handheld unit, battery charger,
e x t e n s i o n w a n d , s p a r e f i l t e r s ,
voltage output cable, accessories
for calibration, and sensor module
keeper for four sensors in a carrying
case. Sensor modules sold separately.
Portable Unit, HEP1.
GAS SENSOR ACCESSORIES
Sensor Element Shield
The Sensor Element Shield can be screwed on to the
end of the gas sensor to help protect the sensor from
rain, dust, hose directed water, and debris floating in
the air. It can be installed on the Standard, Harsh and
Extreme gas sensors. The shield may slow response
time slightly depending on the surrounding air flow
conditions. Shield, p/n 31-1002.
Harsh Model with Shield
Quick Disconnect Plug Kit
The Quick Disconnect Plug Kit can be added to the gas
sensor to provide a means of easily removing the gas
sensor for recalibration. This feature comes in handy
for gas sensors installed in blast cells, low temperature
rooms and hard-to-reach places. The gas sensor
cable can be quickly disconnected and the entire gas
sensor removed or replaced with a bench recalibrated
gas sensor. The gas sensor can then be brought to an
alternate location for recalibration or sensing element
replacement. Quick Disconnect Plug Kit, p/n 31-1001.
Option only available for field installation. Supplied
cable is 2 feet (0.6 meters) in length.
Harsh Model with Quick Disconnect Plug Kit
2
SHIELD
QUICK DISCONNECT
PLUG KIT