Unipro UniTire V2 User Manual

Unipro UniTire V2 User Manual

Pressure gauge

Advertisement

Quick Links

UniTire V2 Pressure Gauge
User Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UniTire V2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unipro UniTire V2

  • Page 1 UniTire V2 Pressure Gauge User Guide...
  • Page 2: Important Safety Instructions

    Important safety instructions S a f e t y PLEASE READ THE SAFETY INSTRUCTIONS CAREFULLY • Read the instructions. • Keep these instructions. • Follow all instructions. • Do not use the UniTire in water. • Be careful not to drop it on the ground. •...
  • Page 3: Table Of Contents

    Contents C o n t e n t s IMPORTANT SAFETY INSTRUCTIONS GAUGE MODE SETUP CONTENTS MAX RANGE SETUP COPYRIGHT AND ACKNOWLEDGEMENTS IV STEALTH MODE SETUP SALES AND SERVICE IN DENMARK STEALTH TARGET SETUP INTERNATIONAL DEALERS LANGUAGE SETUP DESIGN AND PRODUCTION CONTRAST SETUP ABOUT THIS USER GUIDE OPERATION SETUP...
  • Page 4: Copyright And Acknowledgements

    This guide was written and produced by Unipro ApS. Unipro ApS Viborg Hovedvej 24 UniTire V2 User Guide version 2.00 DK-7100 Vejle Denmark Made for UniTire V2 firmware version 1.0x. Tel +45 7585 1182 COPYRIGHT mail@uniprolaptimer.com www.uniprolaptimer.com Copyright © 2022 Unipro ApS www.facebook.com/uniprolaptimer www.instagram.com/uniprolaptimer...
  • Page 5: Introduction

    I n t r o d u c t i o n Introduction This User Guide contains all relevant information about your new UniTire digital tire pressure gauge. Get started with the UniTire in 2 minutes with the Quick Guide. Read all about the advanced features and functions in the Reference Guide.
  • Page 6: Overview

    Enables both right and left handed operation. STANDARD BATTERIES BLUETOOTH Two standard AAA Alkaline Transfer data to the batteries inside. Long Unipro app on your lifetime. phone or tablet. HIGH PRECISION HANDLE CABLE 0.0002 bar resolution Flexible cable with power and 0.01 bar typical...
  • Page 7: Specifications

    10 bar (145 psi) Wasted air 0.8 cm (0.05 inch Communication Bluetooth (BLE) Real time clock Yes (auto sync with Unipro app) Power supply 2 x AAA Alkaline batteries Battery lifetime ~ 200 hours** Pressure units bar, mbar, psi, HPa, Torr...
  • Page 8: Examples

    Examples I n t r o d u c t i o n...
  • Page 9: Quick Guide

    Q u i c k G u i d e Quick Guide Read the Quick Guide and learn how to use the basic functions of the UniTire: Turn UniTire on and off, view current tire pressure, save the pres- sure values for all tires and recall them later. You will be ready to go in 2 minutes...
  • Page 10: Save The Measured Pressure Values

    Quick guide Q u i c k G u i d e SAVE THE MEASURED TRANSFERRING DATA PRESSURE VALUES From “Recall mode” press the left button ( ) to go to “Transfer mode”. If you start in “Sequence mode”, the screen will inform you about which tire you are sup- While the transfer screen is active, the posed to measure.
  • Page 11: G Uide

    R e f e r e n c e G u i d e Reference Guide In the reference guide you can find detailed information about all features and functions of the UniTire. To get the most from your UniTire, we recommend that you read this guide in full.
  • Page 12: Ways To Press Buttons

    The current time and date is also shown on the power off screen. This clock can only be set TURN UNITIRE ON from the Unipro app. There are 3 different ways to turn UniTire on: When you turn UniTire off, you will have access to the built-in help.
  • Page 13: Pressure Mode

    R e f e r e n c e Operating UniTire G u i d e PRESSURE MODE The history list will be saved even when UniTire is turned off. The regular tire pressure gauge simply shows the current tire pressure and continuously If you want to clear the history, press and hold updates when air is released by pressing one down the left button (...
  • Page 14: Sequence Mode

    Also when using the analog gauge mode, you ferred to the Unipro app via BLE. press the right button ( ) to save the value and move on to the next tire.
  • Page 15: Stealth Mode

    R e f e r e n c e Operating UniTire G u i d e STEALTH MODE Digital gauge view in Stealth mode Stealth mode is an alternative way of using the Sequence mode. The purpose with Stealth mode is to make it impossible for your competitors to see your tire pressure when you are measuring.
  • Page 16 R e f e r e n c e Operating UniTire G u i d e Digital gauge view in Stealth mode If you want to start over with the current sequence, press and hold the left button ( down until the circle shows the first tire again. When you save the measured values in Stealth mode, the actual values are stored in the memory, so you will be able...
  • Page 17: Recall Mode

    “CONNECTABLE” means that UniTire is ready to connect to your phone running the Unipro Each page in Recall mode can show four App. “UniTire_1293” is the Bluetooth name different sequences with either 2 or 4 tires in including the serial number.
  • Page 18 R e f e r e n c e Operating UniTire G u i d e To go back to either Sequence mode or Stealth mode, press the left button ( ) again. Transfer screen, connected to the app. When the app is connected, it now controls UniTire.
  • Page 19: Enter Setup Mode

    R e f e r e n c e Setup mode G u i d e ENTER SETUP MODE by pressing the right button ( ). You enter Setup mode by pressing both the When the sport is changed, overwriting values left and right buttons at the same time needs to be confirmed on the next screen.
  • Page 20: Max Range Setup

    R e f e r e n c e Setup mode G u i d e Scroll between choices by pressing the left button ( ). Select and move to next setup screen by pressing the right button ( ). MAX RANGE SETUP If UniTire is set to operate in analog mode, it is necessary to set the maximum pressure value...
  • Page 21: Language Setup

    R e f e r e n c e Setup mode G u i d e STEALTH OFFSET SETUP button a little longer ( When Stealth mode is enabled, it is possible to Scroll through the choices with the left but- offset the value shown in Pressure mode.
  • Page 22: Operation Setup

    R e f e r e n c e Setup mode G u i d e button ( ). Select and move on to the next setup screen by pressing the right button ( ). AUTO OFF TIME SETUP UniTire will automatically be turned off after not being used for a preselected amount of time.
  • Page 23: Troubleshooting

    If you have any problems, either with the setup or with daily use, please check the following pages for suggested solutions. If you don’t find the answer to the problem here, please contact your Unipro dealer for further assistance. Weak and hard to read text UniTire is not turning on The contrast is set too low.
  • Page 24: Battery Change

    Maintenance M a i n t e n a n c e Battery change Cleaning To replace batteries To clean the case, display, and buttons When the batteries reach 2.2 V, the low bat- The exterior surfaces of UniTire products are tery symbol will be shown at the bottom of the made from solid anodized aluminum, plastic display:...
  • Page 25: Service

    M a i n t e n a n c e Service Guarantee The Unipro UniTire pressure gauge has been The product is guaranteed against defects in carefully designed to give you many years of material and workmanship for two years from untroubled use.
  • Page 26: Index

    Index I n d e x Examples, screenshots 8 Accuracy, typical 7 Acknowledgements IV Firmware version IV, 12 Alkaline batteries 24 Analog gauge mode 13 Analog stealth mode 16 Gauge mode setup 19 Guarantee 25 Batteries 11 Battery change 24 Battery lifetime 7 Handle 11 BLE, connectable 17...
  • Page 27 I n d e x Power supply 7 Setup, stealth target 20 Preface II Spare part number IV Pressure mode, analog 13 Specifications 7 Pressure mode, digital 13 Sport setup 19 Pressure not zero 23 Stealth mode 15 Pressure range 7 Stealth mode, analog 16 Pressure units 7 Stealth mode, digital 15...
  • Page 28 Unipro ApS • Viborg Hovedvej 24 • DK-7100 Vejle • Denmark Tel: +45 7585 1182 www.uniprolaptimer.com...

This manual is also suitable for:

17-02-00417-02-00317-02-001

Table of Contents