ANTENNA MULTIPLEXING/CHECK TAG PORT
1
Recommended Data Cable: 9-pin ribbon cable
Recommended Check Tag Antenna Cable:
50-ohm coaxial cable (3 dB loss in cable)
Encompass 5 jack is DB9 socket connector
Pin 9
Pin 1
Pin 2
TDM/COM1 PORT
2
Recommended COM1 Port Data Cable: 20 AWG cable
Recommended TDM Cable: Belden 89182 (outdoor-rated)
Recommended TDM Cable: Belden 8132 (not outdoor-rated)
Mating connector (TransCore P/N 33357-01)
Installed on Encompass 5 jack
COM2 PORT
3
Recommended Cable: 20 AWG cable
Encompass 5 jack is DB9 plug connector
Pin 9
Pin 1
Pin 2
ANTENNA PORT
4
Recommended Cable: 50-ohm coaxial cable
AA3152 Universal Toll Antenna recommended
NOTE
:
Use the RF MONO port for single-antenna installation
CAUTION: Tighten antenna SMA connector to
10 in/lb only. Do not cross-thread the
connectors when ti g htenin g .
ETHERNET PORT
5
Recommended Data Cable: Belden 7929A Paired
Category 5e (outdoor-rated)
Maximum Length: 330 feet (100 m)
RJ-45 jack
®
FAULT/OPERATIONAL LEDs
(see other side
for descriptions )
1
2
3
POWER LEDs
11
10
(see other side
for descriptions)
11
10
6
4
5
DIAGNOSTIC TEST PORT
Used for factory diagnostic testing only
EXTERNAL DIGITAL INPUT/OUTPUT PORT
Data Cable: 20 AWG wire
Mating Connector (TransCore P/N 33357-01)
Installed on Encompass 5 jack
GPS TIMING PORT
Data Cable: 20 AWG wire
Antenna Cable: 50-ohm coaxial cable
12 dB @1.575 GHz
Pin 1
Pin 6
POWER REQUIREMENTS
Input Supply Voltages
19V DC to 30V DC or
19V AC to 27V AC RMS @47 to 63 Hz
Input Power
DC or AC: 40 watts maximum
In-rush Current
8 amps (A) maximum,
Transformer: (TransCore P/N 76-6000-001)
110V AC or 220V AC input, 24V AC output
Power Cable: 12-22 AWG cable
Mating Connector (TransCore P/N 33356-01)
(1 each) and P/N 33358-01 (2 each) installed
on Encompass 5 jack
CAUTION: Wire gauge depends on wire resistance
9
versus overall wire length with respect to the
Encompass 5 reader's specified voltage range
8
and power rating.
( See other side for Choosin g a Power Su pp l y)
7
Loosen mounting screws before
6
7
8
Pin 5
Pin 10
9
25 milliseconds (ms)
CAUTION:
removing plug.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Encompass 5 and is the answer not in the manual?

Questions and answers

Summary of Contents for TransCore Encompass 5

  • Page 1 50-ohm coaxial cable (3 dB loss in cable) Data Cable: 20 AWG wire FAULT/OPERATIONAL LEDs POWER LEDs Mating Connector (TransCore P/N 33357-01) Encompass 5 jack is DB9 socket connector (see other side (see other side Installed on Encompass 5 jack for descriptions )
  • Page 2 Encom p ass 5 reader’s s p ecified volta g e ran g e and p ower ratin g . THREE FAULT INDICATION LEDs Perform the following startup procedures: ERR3 ERR2 ERR1 FAILURE MODE 1. Connect antenna to Encompass 5 at RF MONO port.    Microprocessor resetting 2. Connect COM1 or Ethernet cable depending on ...