3.2 Sen-XY-f and Sen-Z-f Characteristics

Table 3-2: Sen-XY-f and Sen-Z-f Absolute Maximum Ratings

Parameter
Input Pin Current @ 25 C
Voltage Across Coil
Storage Temperature
CAUTION:
Stresses beyond those listed above may cause permanent damage to the device. These
are stress ratings only. Assuming operation with the MagI2C per the guidelines in this
manual, these maximum ratings will not be violated.
Parameter
1
Inductance
DC resistance @ 25C 15C
Resistance versus
temperature
Weight
Operating Temperature
Footnote:
1. 1 V peak-to-peak across the coil @ 100 kHz sinewave.
Measured orthogonal to Earth's magnetic field.
PNI Sensor Corporation
RM3100 & RM2100 Sensor Suite User Manual
Minimum

Table 3-3: Sen-XY-f and Sen-Z-f Characteristics

Min
30
Sen-XY-f
Sen-Z-f
-40
Maximum
50
2.0
-40
+85
Typical
Max
500-600
45
0.4
0.06 [0.002]
0.09 [0.003]
+85
Units
mA
VDC
C
Units
H
%/C
gm [oz]
gm [oz]
C
No DC bias resistance.