ABB BSM50N Installation And Operating Manual page 19

Brushless servo motors
Table of Contents

Advertisement

Motor-SSi
BSMxxx-xxxxS1 or S2
Terminal block
Ground
boss
1
2
3
4
U
V
W
Standard motor
connector
B
C
A
D
4
1
3
2
Standard SSI
connector
12 Pin
1
9
8
2
10
12
7
3
11
6
4
5
Note
For BSM 50/63/80 (and option on BSM90/100), the standard and rotatable power connector is rated
at 28 amps .
BSM brakes are not polarity sensitive .
2-12
Figure 2-10 Typical Connections to Feedback Termination
Power connections
BSM 90/100
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
Power connections
BSM 50/63/80 and SSBSM
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
SSI connections
BSM and SSBSM
Post
Function
1
+Vs (5Vdc)
2
OV
3
SSI clock
4
SSI clock
5
SSI DATA
6
SSI DATA
7
8
9
Connected to
pin 1
10
11
12
Motor-Hiperface
BSMxxx-xxxxD3 or D4
Terminal block
Ground
boss
1
2
3
4
U
V
W
Standard motor
connector
B
C
A
D
4
1
3
2
Standard hyperface
connector
12 Pin
1
9
8
2
10
12
7
3
11
6
4
5
Power connections
BSM 90/100
Post
Function
1
Thermal switch
2
Thermal switch
3
Brake (optional)
4
Brake (optional)
U1
Motor lead U
V2
Motor lead V
W3
Motor lead W
Screw
Ground
Power connections
BSM 50/63/80 and SSBSM
Post
Function
A
Thermal switch
B
Thermal switch
C
Brake (optional)
D
Brake (optional)
1
Motor lead U
2
Ground
3
Motor lead W
4
Motor lead V
Hyperface connections
BSM and SSBSM
Post
Function
1
DATA-
2
+SIN
3
Open
4
+COS
5
OPEN
6
OPEN
7
OPEN
8
REF COS
9
US 7-12V
10
GND
11
REF SIN
12
DATA+
MN1240

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bsm63nBsm80Bsm90Bsm100Bsm25cBsm33c ... Show all

Table of Contents