KitchenAid Architect Series II KERS206X Specifications

30" (76.2 cm) freestanding range
Hide thumbs Also See for Architect Series II KERS206X:

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
KERS206X
KERS308X
KERS208X
ELECTRICAL REQUIREMENTS
This range is manufactured with the neutral terminal connected to the cabinet. Use
a 3-wire UL listed, 40- or 50-amp power supply cord (pigtail) (see Range Rating
chart below). If local codes do not permit ground through the neutral, use a 4-wire
power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with
ranges.
Range Rating*
Protection
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW
12.6 - 18.5 KW
**
The NEC calculated load is less than the total connected load listed on the
model/serial rating plate.
**
If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp
rated cord kits, use kits that specify use with a nominal 1 " (34.9 mm) diameter
connection opening.
A circuit breaker is recommended.
The range can be connected directly to the fused disconnect (or circuit breaker
box) through flexible or nonmetallic sheathed, copper or aluminum cable.
Wire sizes and connections must conform with the rating of the range (40 amps).
CABINET DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.
IMPORTANT:
If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions
for dimensional clearances above the cooktop surface.
NOTE:
24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than
MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
30" (76.2 cm) Freestanding Range
Specified Rating of
Power Supply Cord
Kit and Circuit
Amps
40 or 50**
50
C
A
B
D
F
I
G
H
F
E
OVERALL DIMENSIONS
A
F
J
" (0.64 cm) flame retardant millboard covered with not less than No. 28
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
C
E
D
**
Range can be raised approximately "
(1.9 cm) by adjusting the leveling legs.
B
Anti-tip bracket:
Anti-tip bracket must be securely
mounted to subfloor or wall.
Thickness of flooring may require
longer screws to anchor bracket to
subfloor. Longer screws are available
from your local hardware store.
Ref: 316454912A
10/7/11