Siemens SENTRON 3WL Reference Manual page 28

Air circuit breakers
Hide thumbs Also See for SENTRON 3WL:

Advertisement

3WL Air Circuit Breakers
3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
General data
Size
Type
Rated current I
at 40 °C, at 50/60 Hz
n
Main conductor
N conductor (only on 4-pole versions)
Rated operational voltage U
at 50/60 Hz
e
(for 1000 V version see Catalog LV 1, "Options")
Rated insulation voltage U
i
Rated impulse withstand voltage U
• Main current paths
• Auxiliary circuits
• Control circuits
Isolating function acc. to EN 60947-2
Utilization categories
Permissible ambient temperature
• During operation (in operation with LCD max. 55 °C)
• During storage (special conditions for LCDs must be observed)
6)
• Up to 55 ° C (Cu bare)
Permissible load
• Up to 60 ° C (Cu bare)
• Up to 70 ° C (Cu black painted)
Rated rotor operational voltage U
er
Power loss at I
n
With 3-phase symmetrical load
• Fixed-mounted circuit breakers
• Withdrawable circuit breakers
Operating times
• Make-time
• Opening time
• Electrical make-time (through closing solenoid)
• Electrical opening time (through shunt release)
• Electrical opening time (instantaneous undervoltage release)
• Opening time due to ETU, instantaneous short-circuit release
Endurance
• Mechanical (without maintenance)
3)
• Mechanical (with maintenance)
• Electrical (without maintenance)
• 1000 V version, electrical (without maintenance)
7)
• 1150 V version, electrical
(without maintenance)
3)
• Electrical (with maintenance)
Switching frequency
• 690 V version
• 1000 V version
7)
• 1150 V version
Minimum interval between tripping operation by solid-state
release and next making operation of the circuit breaker (only
with automatical mechanical resetting of the lockout device)
Mounting position
Degree of protection
Main conductor
• Copper bars,
minimum
bare
cross-sections
• Copper bars,
painted black
Auxiliary conductors
Standard connection = strain-relief clamp
(Cu)
• Without end sleeve
Max. number of
• With end sleeve acc. to DIN 46228 Part 2
auxiliary conductors ×
• With twin end sleeve
cross-section
(solid/stranded)
Optional connection = tension spring
• Without end sleeve
• With end sleeve acc. to DIN 46228 Part 2
Position indicator swit-
Tension spring terminals
ches
Weights 3-pole
• Fixed-mounted circuit breakers
• Withdrawable circuit breakers
• Guide frames
4-pole
• Fixed-mounted circuit breakers
• Withdrawable circuit breakers
• Guide frames
1) Opening time on instantaneous short-circuit release with
ETU15B = 85 ms.
2) Make-time through closing solenoid for synchronization purposes
(short-time excited) 50 ms.
3) Maintenance means: replace main contact elements and arc chutes
Operating Manual).
28
Siemens · 2009
II
3WL12 25
A
2500
A
2500
V AC ... 690/1000
V AC 1000
imp
kV
12
kV
kV
Yes
B (except switching capacity class DC)
4)
° C
–25/+70
° C
–40/+70
A
2500
5)
A
2500
5)
A
2280
V 2000
W
270
W
520
ms
ms
2)
ms
100
ms
ms
ms
10000
Oper. cycles
Oper. cycles
15000
Oper. cycles
Oper. cycles
Oper. cycles
Oper. cycles
15000
1/h
60
1/h
20
1/h
20
ms 80
IP20 without cabinet door, IP41 with door sealing frame, IP55 with cover
Units
2 ×
2
mm
100 × 10
Units
2 ×
2
mm
100 × 10
2 × 0.5 mm
1 × 0.5 mm
2 × 0.5 mm
2 × 0.5 mm
2 × 0.5 mm
1 × 0.5 mm
kg
59
kg
63
kg
39
kg
71
kg
76
kg
47
(see
3WL12 32
3WL12 40
3200
4000
3200
4000
... 690/1000
... 690
1000
1000
12
12
4
4
4
2.5
2.5
2.5
Yes
Yes
–25/+70
–25/+70
–40/+70
–40/+70
3200
3950
3020
3810
2870
3600
2000
2000
410
750
710
925
35
35
35
34
34
34
100
100
73
73
73
73
73
73
1)
1)
1)
50
50
50
10000
10000
15000
15000
7500
4000
4000
1000
1000
1000
500
500
500
15000
15000
60
60
20
20
20
20
80
80
3 0 ° 3 0 °
3 0 °
3 0 °
and/
or
N S E 0 _ 0 0 0 6 1 a
N S E 0 _ 0 0 0 6 2 a
3 ×
4 ×
100 × 10
120 × 10
3 ×
4 ×
100 × 10
100 × 10
2
2
(AWG 20) ... 2 × 1.5 mm
2
2
(AWG 20) ... 1 × 1.5 mm
2
2
(AWG 20) ... 2 × 1.5 mm
2
2
(AWG 20) ... 2 × 2.5 mm
2
2
(AWG 20) ... 2 × 1.5 mm
2
2
(AWG 20) ... 1 × 2.5 mm
64
85
68
121
45
52
77
103
82
146
54
62
4) Use of releases from –20 °C.
5) ETU76B with graphics display can be used up to max. 55 °C.
6) 4000 A, size II in fixed-mounted version, 3-pole.
7) Size III: data for very high switching capacity.
8) Minimum main conductor cross-sections for 4-pole withdrawable circuit
breakers: 4 x 120 x 10 mm.
III
3WL13 40
3WL13 50
3WL13 63
4000
5000
6300
4000
5000
6300
... 690/1000
... 690/1000
... 690/1000
1000
1000
1000
12
12
12
4
4
4
2.5
2.5
2.5
Yes
Yes
Yes
–25/+70
–25/+70
–25/+70
–40/+70
–40/+70
–40/+70
4000
5000
5920
4000
5000
5810
4000
5000
5500
2000
2000
2000
520
630
900
810
1050
1600
35
35
35
34
34
34
100
100
100
73
73
73
73
73
73
50
50
50
5000
5000
5000
10000
10000
10000
2000
2000
2000
1000
1000
1000
1000
1000
1000
10000
10000
10000
60
60
60
20
20
20
20
20
20
80
80
80
N S E 0 _ 0 0 9 2 7 a
4 x
6 x
6 x
100 x 10
100 x 10
120 x 10
4 ×
6 ×
6 ×
8)
100 × 10
100 × 10
120 × 10
2
(AWG 16); 1 × 2.5 mm
(AWG 14)
(AWG 16)
(AWG 16)
(AWG 14)
(AWG 16)
(AWG 14)
82
82
90
88
88
96
60
60
70
99
99
108
106
106
108
84
84
119