Selecting a Mode
The CX-WC13PS has two Restroom applications built in (Mode
7 & 8). The default mode for the CX-WC13PS is Mode 7
(normally unlocked).
Determining which mode is correct for you will be based on
whether the Restroom will be normally unlocked (Mode 7) or
normally locked (Mode 8).
There are three LED displays that will allow you to see what mode
you have selected when advancing through the modes. To change
the mode of the CX-WC13PS simply press the MENU button once
and use the UP button to advance to the desired mode.
Editing the Settings for a Mode
Camden builds in typical times for lock release and door
operator activation and is ready to use without changing any
parameters. If you need to change the timing or delay for an
output, it can be done by pressing the "MENU" button within the
mode you selected. Once the option is selected you can use the
"UP or DOWN" buttons to select the timing needed.
Display (M)
H, then 1
d, then 1
H, then 1
d, then 1
H, then 1
d
Input delay on Activate. If other than 0.0 is selected, the input must
A
be held in for the time period chosen before the CX-33 will activate.
1
Set Dry Input 1 to activate on normally open or normally closed contact.
2
Set Dry Input 2 to activate on normally open or normally closed contact.
3
Set Dry Input 3 to activate on normally open or normally closed contact.
4
Set Dry Input 4 to activate on normally open or normally closed contact.
5
Set Dry Input 5 to activate on normally open or normally closed contact.
Description ( Mode you are in)
Relay 1 Hold Time
Relay 2 Delay Time
Relay 2 Hold Time
Relay 3 Delay Time
Relay 3 Hold Time
Sets the display ON or OFF during operating mode
WC13PS SERIES RESTROOM CONTROL
The first option (H & 1 flashing) will be how long relay 1 will be
activated for (0-50 seconds). The second option (d & 1 flashing)
will be how long to wait before activating relay 2 (0-15 seconds).
The third option (H & 2 flashing) will be how long relay 2 will be
activated for (0-50 seconds). The fourth option (d & 2 flashing)
will be how long to wait before activating relay 3 (0-15 seconds).
The fifth option (H & 3 flashing) will be how long relay 3 will be
activated for (0-50 seconds). See chart below.
Factory Reset (Defaulting the CX-33)
To return the CX-33 back to its factory default settings you will
need to remove power, then hold down the "MENU" button
while powering up the CX-33. Once started you will see the
firmware version listed then a number "1" will be displayed.
Reconnect your power and press the "MENU" button once then
use the "UP" or "DOWN" button to advance to the desired mode.
Fully test the operation of the CX-WC13PS for proper functionality.
IN S TALL AT ION INSTRUCTIO NS
Parameters ( 1-15 )
0.0 to 50 seconds
0.0 to 15 seconds
0.0 to 50 seconds
Depends on Mode
0.0 to 50 seconds
ON or OFF
0.0 to 10 seconds
N/O OR N/C
N/O OR N/C
N/O OR N/C
N/O OR N/C
N/O OR N/C