Nortek T4QE Installation Instructions Manual

Split system heat pump for manufactured housing

Advertisement

Split SyStEm hEat pump foR manufactuREd houSing
inStallation inStRuctionS
t4QE - 024Ka, 030Ka, 036Ka, 042Ka, & 048Ka (2, 2.5, 3, 3.5, & 4 ton) modElS
SinglE phaSE SERiES
impoRtant SafEty infoRmation ............................ 2
hEat pump inStallation ........................................... 3
General Information ......................................................... 3
Before You Install the Heat Pump ................................... 3
Locating the Heat Pump .................................................. 3
Packaging Removal ......................................................... 3
Ground Level ................................................................... 3
Rooftop ............................................................................ 3
Outdoor Unit .................................................................... 4
ElEctRical WiRing ...................................................... 4
Pre-Electrical Checklist ................................................... 4
Line Voltage ..................................................................... 4
Grounding ........................................................................ 5
Thermostat / Low Voltage Connections .......................... 5
StaRt up & adJuStmEntS ......................................... 6
Pre-Start Check List ........................................................ 6
Start-Up Procedures ........................................................ 6
Operating Temperatures ................................................ 6
Air Circulation - Indoor Blower ....................................... 6
Short Cycle Protection ................................................... 6
System Cooling ............................................................. 6
System Heating ............................................................. 6
Defrost Control Board Test Pins ...................................... 6
it is your responsibility to know this product better than your customer. this includes being able to install the product
according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for
the life of the product. Safety should always be the deciding factor when installing this product and using common
sense plays an important role as well. pay attention to all safety warnings and any other special notes highlighted
in the manual. improper installation of the furnace or failure to follow safety warnings could result in serious injury,
death, or property damage.
these instructions are primarily intended to assist qualified individuals experienced in the proper installation of this
appliance. Some local codes require licensed installation/service personnel for this type of equipment. please read all
instructions carefully before starting the installation. Return these instructions to the customer's package for future
reference.
do not dEStRoy. plEaSE REad caREfully & KEEp in a SafE placE foR futuRE REfEREncE.
hEat pump maintEnancE .......................................... 7
REfRigERant chaRging ............................................ 7
Charging the Unit in AC Mode ......................................... 7
Application Notes & Charging Charts.............................. 8
Figure 3. Charging Chart for 2 Ton Models .................... 8
Figure 4. Charging Chart for 2.5 Ton Models ................. 9
Figure 5. Charging Chart for 3 Ton Models .................... 9
Figure 6. Charging Chart for 3.5 Ton Models ................. 10
Figure 7. Charging Chart for 4 Ton Models .................... 10
Table 6. Verification Table for 2 Ton Models ................... 12
Table 7. Verification Table for 2.5 Ton Models ................ 12
Table 8. Verification Table for 3 Ton Models ................... 12
Table 9. Verification Table for 3.5 Ton Models ................ 13
Table 10. Verification Table for 4 Ton Models ................. 13
WiRing diagRam ........................................................... 14
Figure 8. W.D. for 2 - 4 Ton Models ................................ 14
REplacEmEnt paRtS ................................................... 16
impoRtant
attEntion inStallERS:
14 SEER

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T4QE and is the answer not in the manual?

Questions and answers

Summary of Contents for Nortek T4QE

  • Page 1: Table Of Contents

    Split SyStEm hEat pump foR manufactuREd houSing 14 SEER inStallation inStRuctionS t4QE - 024Ka, 030Ka, 036Ka, 042Ka, & 048Ka (2, 2.5, 3, 3.5, & 4 ton) modElS SinglE phaSE SERiES impoRtant SafEty infoRmation ......2 hEat pump maintEnancE .......... 7 hEat pump inStallation ...........
  • Page 2: Important Safety Information

    impoRtant SafEty infoRmation WaRning: INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and unless noted otherwise in these instructions, any other special notes highlighted in the manual. Safety only factory authorized parts or accessory markings are used frequently throughout this manual to kits may be used with this product.
  • Page 3: Heat Pump Installation

    hEat pump inStallation packaging Removal To prevent damage to the tubing onnections, carefully general information remove the carton and user’s manual from the equipment. Split system heat pumps are designed only for outdoor Discard the shipping carton. rooftop or ground level installations. This unit has been tested for capacity and efficiency in accordance with ground level AHRI Standards and will provide many years of safe...
  • Page 4: Connecting Refrigerant Tubing Between The Indoor & Outdoor Unit

    Connecting Refrigerant Tubing Between caution: the indoor & outdoor unit to prevent damage to the unit or internal caution: components, it is recommended that two wrenches be used when loosening or tightening When servicing, cover or seal openings to nuts. do not over tighten! minimize the exposure of the refrigerant system to air to prevent accumulation of moisture and 4.
  • Page 5: Grounding

    on the outdoor unit data label. Any other wiring methods • The thermostat should be mounted about 5 feet above must be acceptable to authority having jurisdiction. the floor on an inside wall. DO NOT install the thermostat • The outdoor unit requires both power and control circuit on an outside wall or any other location where its electrical connections.
  • Page 6: Start Up & Adjustments

    StaRt up & adJuStmEntS 3. After approximately 5 minutes, verify the outdoor unit energizes and the temperature of the discharge air is pre-Start check list cooler than the room temperature. √ Verify the unit is level and has sufficient clearances for unobstructed airflow.
  • Page 7: Heat Pump Maintenance

    hEat pump maintEnancE • Cooling mode charging charts and tables are applicable only to matched assemblies of this equipment and listed airflows for the indoor coil. Refer to the Quick Reference WaRning: Data sheet for additional charging information. Outdoor units with non-AHRI listed indoor coils are not to prevent electrical shock, personal injury, or recommended and deviations from rated airflows or death, disconnect all electrical power to the unit...
  • Page 8: Application Notes & Charging Charts

    Before using these charts, make instructions for more information. (If applicable) sure the unit is in a stable operating mode. As shown in T4QE-024KA CHARGING CHART - COOLING Remove refrigerant if above curve Add refrigerant if below curve Liquid Temperature (°...
  • Page 9 T4QE-024KA CHARGING CHART - COOLING Remove refrigerant if above curve Add refrigerant if below curve Liquid Temperature (° F) figure 4. charging chart for 2.5 ton models (TXV Matches) T4QE-036KA CHARGING CHART - COOLING Remove refrigerant if above curve Add refrigerant if below curve Liquid Temperature (°...
  • Page 10 T4QE-042KA CHARGING CHART - COOLING Remove refrigerant if above curve Add refrigerant if below curve Liquid Temperature (° F) figure 6. charging chart for 3.5 ton models (TXV Matches) T4QE-048KA CHARGING CHART - COOLING Remove refrigerant if above curve Add refrigerant if below curve Liquid Temperature (°...
  • Page 11: Application Notes & Heat Mode Verification Tables

    Shaded boxes indicate flooded conditions. Rated design values. The suction pressure will vary from design value if outdoor air flow, entering dry bulb, or entering wet bulb temperatures vary. 1. All pressures are listed in psig and all temperatures in ° F 2.
  • Page 12 outdooR tEmpERatuRE (dEg. f) 37 200 207 98 52 220 228 108 67 240 248 118 83 260 268 128 99 270 278 138 117 293 301 148 135 316 324 158 38 207 214 96 53 226 234 106 68 245 253 116 84 264 272 126 100 277 285 135 118 300 308 143 136 323 331 152 39 214 221 94 54 232 239 104 69 250 257 114 85 268 275 124 101 284 292 132 119 307 315 139 137 330 338 146 40 221 228 92...
  • Page 13 outdooR tEmpERatuRE (dEg. f) 30 210 217 119 45 234 241 123 61 258 265 128 77 281 289 132 92 298 305 142 108 330 337 156 123 363 370 171 31 217 224 117 46 240 247 121 62 262 270 126 78 285 292 130 93 305 312 139 109 337 344 152 124 370 377 165 32 224 231 115 47 246 253 119 63 267 274 124 79 289 296 128 94 312 319 136 110 344 351 147 125 377 384 158 33 231 238 113 48 252 259 117 64 272 279 122 80 292 300 126 95 319 326 133 111 351 358 143 126 384 391 152 34 238 245 111 49 257 265 115 65 277 284 120 81 296 303 124 96 326 333 130 112 358 365 138 127 391 398 146...
  • Page 14: Wiring Diagram

    WiRing diagRam YELLOW YELLOW BLACK figure 8. W.d. for 2 - 4 ton models...
  • Page 16: Installation / Performance Check List

    Blower Motor Fan Motor componEntS: Blower Assembly Fan Grille Cabinet Panels Filter/Driers Expansion Valves Specifications & illustrations subject to change without notice or incurring obligations (05/15). 709762a (Replaces 7097620) O’Fallon, MO, © Nortek Global HVAC LLC 2015. All Rights Reserved.

This manual is also suitable for: