Page 1
DVI input Kit for iCon Installation Manual R9843030 R5976887/00 29/03/2006...
Page 2
Barco nv Presentations Noordlaan 5, 8520 Kuurne Phone: +32 56.36.82.11 Fax: +32 56.35.86.51 E-mail: presentations.bid@barco.com Visit us at the web: www.barco.com Printed in Belgium...
Page 3
The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning, at latest 30 days after the transfer of risks. In the event of justified notice of complaint, Barco can repair the fault or provide a replacement at its own discretion within an appropriate period.
1. Safety 1. SAFETY Safety warnings ARNING This procedure is intended for use only by BARCO authorized technicians. ARNING Be sure that the projector is powered down and that the power cord is removed from the wall outlet. Wait until the projector is cooled down before starting the procedure.
Page 8
1. Safety R5976887 DVI INPUT KIT FOR ICON 29/03/2006...
Description • kit contents Description Purpose The DVI input board kit allows to add/replace in a Barco iCon projector : • 1 DVI input on DVI connector • 1 RGBHV input on D15 connector The flexibility of the iCon input section allows to add this input on one of the 4 input slots provided on the backplane (PMP).
Page 10
2. Kit description Image 2-3 R5976887 DVI INPUT KIT FOR ICON 29/03/2006...
3. DVI input (re)placement 3. DVI INPUT (RE)PLACEMENT Overview • Accessing the input section • Replacing the DVI input Upgrade/replacement The following procedure illustrates the replacement of a DVI input board. The same operations must be done in case one wants to add a second DVI input to the projector.
3. DVI input (re)placement How to install the cable basket 1. Place the 2 feet of the cable basket into the 2 bottom locks of the projector. Image 3-2 2. Bring the basket towards the projector and press on it so as to lock it at the top. 3.1.2 Removing the lens cover Necessary tools...
3. DVI input (re)placement Image 3-4 Image 3-5 Detail of the lens locking handle and pin 3. Pull out the locking pin and flip the lens locking handle to the right (with the index finger) at the same time. 4. Pull the lens gently out of the lens holder. 3.1.4 Removing the rear cover Necessary tools...
3. DVI input (re)placement Image 3-7 2. Loosen and remove the 2 front screws Image 3-8 3. Loosen and remove the indicated screw Image 3-9 4. Remove the top cover and disconnect the local keypad connector. 3.1.6 Removing the filter front plate Necessary tools Torx n°10 How to remove the filter front plate...
3. DVI input (re)placement Image 3-10 2. Remove the plate Image 3-11 Note: The plate is fixed in 3 holes 3.1.7 Removing the front plate Necessary tools • Torx n°10 • nut spinner n°5 How to remove the front plate ? 1.
Page 16
3. DVI input (re)placement Image 3-13 3. Remove the 2 screws fixing the USB connectors. Note: the 2 screws are fixed with 2 nuts on the rear of the plate : remove gently the plate forwards to access the nuts. Image 3-14 Tip: In case one must only access the side screws on the PMP it is not necessary to loosen the USB connector.
3. DVI input (re)placement 3.1.8 Removing the Server What has to be done ? Depending on the type of plate 1 piece/2pieces) the removal procedure is slightly different : 1 piece plate : the plate must be removed Image 3-16 1 piece plate 2 piece plate : remove only the side plate (1) , the server can be slided to the side.
Page 18
3. DVI input (re)placement Image 3-18 2. If the plate is in one piece If yes, remove the 4 screws If no, go to step 8 Image 3-19 3. Push the flat cable and the power cable through the hole. Image 3-20 Flat cable and power cable (arrows) and cable bundle 4.
Page 19
3. DVI input (re)placement Image 3-21 6. Remove the second wire bundle from the lower cable protective lock. Image 3-22 7. 1 piece plate : Remove the indicated screws to allow the server to be slided to the side. Image 3-23 R5976887 DVI INPUT KIT FOR ICON 29/03/2006...
Page 20
3. DVI input (re)placement Image 3-24 8. Remove the LVDS connections from the PMP(only in case the server must be completely removed). Image 3-25 9. Remove the ATX power cable from the power box (only in case the server must be completely removed). Image 3-26 10.Remove the Ethernet connection and the small connector from the PMP (only if server must be completely removed).
Page 21
3. DVI input (re)placement Image 3-27 11. Remove the 3 screws fixing the server to the projector frame. Image 3-28 12.Remove the server or place the server on the side in case one must only access the PMP (input side screws) Image 3-29 R5976887 DVI INPUT KIT FOR ICON 29/03/2006...
3. DVI input (re)placement Replacing the DVI input Necessary tools • Torx n°10 • hexagonal nut driver How to remove the DVI input board ? 1. Remove the front plates. 2. Loosen the input front screws and remove the plate. Image 3-30 3.
Page 23
3. DVI input (re)placement Image 3-32 Caution: Tightening the screw too much can damage the connectors ! Tip: When tightening the screw the board will be “pulled” into the connectors hereby lifting and positioning it horizontally. 3. Mount and tighten the side screw (of slot 3 in this case) on the lens side. 4.
Need help?