A complete gas tightness check must be performed at the installation site. Periodically check the
whole system for leaks, or immediately if the smell of gas is present.
1.
Prepare soap solution by combining one part of liquid detergent and one part of water.
2.
Ensure all control valves are in the OFF position before turning the gas supply ON.
3.
Check all connections from the supply line or LP cylinder by applying the solution around the
connection, tubing and end of the manifold.
4.
If bubbles appear to "grow" on any of the connections, you have a gas leak. IMMEDIATELY turn
off the gas supply.
5.
Tighten any leaking connections. Turn gas ON, and recheck. If you cannot stop a gas leak turn
the gas supply OFF, do not use your BRABURA Griddle and contact the shop where you purchase
this appliance.
Advice: before each use of the BRABURA Griddle clean and inspect the hose. If there is evidence of abrasion, wear, cuts, or leaks, the hose must be replaced prior to the appliance being put into