Installation Of The Solar Kit; Selecting An Installation Location; Dimensions And Service Space; Installation Guidelines - Daikin EKSOLHWAVJU Installation And Operation Manual

Solar kit for air to water heat pump system
Table of Contents

Advertisement

I
NSTALLATION OF THE SOLAR KIT

Selecting an installation location

The solar kit is to be installed in a frost free indoor space,
directly connected to the domestic hot water tank.
Make sure the service space is available as indicated in below
drawing.
The space around the unit has to allow sufficient air circulation.
It shall be made sure that in the case of a leak, leaking water will
not cause any damage or unsafe situations.
Do not install or operate the unit in rooms mentioned below:
-
Where corrosive gas like sulphurous gas exists: copper
tubing and brazed spots may corrode.
-
Where volatile flammable gas like thinner or gasoline is used.
-
Where machines generating electromagnetic waves exist:
the control system may malfunction.
-
Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories).
This applies also to vehicles or vessels.

Dimensions and service space

Service space dimensions below relate to requirements for
installation of the solar kit only.
For service space dimensions of the domestic hot water tank, refer to
the domestic hot water tank installation manual.
A
B
EKHWS050
(50 gallons)(200 l)
38.58 inch (980 mm)
EKHWS080
(80 gallons)(300 l)
Installation and operation manual
6
A
B
15.75 inch (400 mm)

Installation guidelines

WARNING
Make sure that all the piping to the solar kit is insulated.
CAUTION
Make sure that all the piping to the solar kit is
sufficiently supported so that it will not cause any stress
on the solar kit.
Make sure the piping is protected against dirt during
installation. Dirt in the piping might clog the heat
exchanger of the solar panel and reduce its
performance.
NOTE
Make sure that the piping coming from outdoors to the solar
kit is put through the wall under an angle and the wall hole is
sufficiently sealed afterwards, so no water can enter the
space.
1
2
3

Installing the solar kit

At delivery, the unit should be checked and any damage should
be reported immediately to the carrier claims agent.
Check if all unit's accessories are enclosed. Refer to
"Accessories supplied with the solar kit" on page
Bring the unit as close as possible to its final installation position
in its original package in order to prevent damage during
transport.
1
Wall
2
Sealing material
3
Piping under an angle
5.
EKSOLHWAVJU
Solar kit for air to water heat pump system
4PW54234-1

Advertisement

Table of Contents
loading