Mounting Position - Honeywell Venturi VR9105V Installation Instructions Manual

Manifold gas controls
Hide thumbs Also See for Venturi VR9105V:
Table of Contents

Advertisement

Available languages

Available languages

Mounting position

The Venturi manifold can be mounted directly on the gas
valve in horizontal or vertical position onto the side outlet,
or in vertical position onto the end outlet. Four screws and
a sealing ring are used. See Fig. 2.
Make sure the Venturis inlet is not obstructed otherwise
this will affect the air factor. If the distance from another
appliance component to the Venturi inlet is more than 2
inches, air factor and appliance load are not influenced.
To prevent blockage from condensation, the air pressure
connection should not be connected to combustion
products.
VENTURI MANIFOLD FOR VR9105V, F AND VR9205V, F GAS CONTROLS
SIDE OUTLET, HORIZONTAL VENTURI
SIDE OUTLET, VERTICAL VENTURI
END OUTLET, VERTICAL VENTURI
Fig. 2. Venturi Manifold mounting.
Table 2. Natural-LP gas conversion kits.
Venturi
Orifice dia. (in.)
45900444-001
45900444-002
45900446-052
Converting Venturi Manifold from
Natural Gas to LP Gas (or LP Gas
to Natural Gas)
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury
or death.
The Venturi manifold can be converted between LP
and Natural gas by changing the orifice. See Table
2.
LPG
Part number
0.236
45900444-110
0.205
45900444-107
0.205
45900444-107
3
M32189
69-2484EF—01