Installation Checklist - Rheem GG50T06PVT Use And Care Manual

Powervent series
Table of Contents

Advertisement

Installation Checklist

A. Water Heater Location
B. Water Supply
C. Gas Supply
D. Relief Valve
E. Venting
20
Close to area of vent.
Indoors and protected from freezing
temperatures.
Proper clearance from combustible surfaces
observed and water heater not installed on
carpeted floor.
Sufficient fresh air supply for proper
operation of water heater.
Air supply free of corrosive elements and
flammable vapors.
Water heater completely filled with water.
Air purged from water heater and piping.
Water connections tight and free of leaks.
Gas line equipped with shut-off valve, union
and sediment trap.
Approved pipe joint compound used.
Soap and water solution used to check all
Temperature and Pressure Relief Valve
properly installed and discharge line run to
open drain.
Discharge line protected from freezing.
F lue baffle properly hung in top of heater's
flue.
Blower assembly properly installed.
Vent connector(s) pitched upward
to chimney
(¼" per foot of length minimum) .
V ent connector(s) securely fastened together
with screws.
Provisions made to protect area from water
damage.
Sufficient room to service heater.
Combustible materials, such as clothing,
cleaning materials, rags, etc. clear of
the base of the heater.
Clearances of 1" from combustion air inlet
openings observed
Flammable vapor sensor is not blocked.
connections and fittings for possible
gas leak.
Gas Company inspected installation (if
required).
Single wall vent connector(s) at least
6" from combustible material.
V apors from PVC cement and primer have
dissipated prior to applying electrical power.