Wiring Diagram - Rheem GG50T06PVT Use And Care Manual

Powervent series
Table of Contents

Advertisement

CONNECTION DIAGRAM
INDUCER
G
N
H
CAUTION! Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
VERIFY PROPER OPERATION AFTER SERVICING!
Wiring
If local codes permit, the water heater
may be connected to electric service with
the power cord provided (DO NOT use an
extension cord). A grounding receptacle is
required.
If local codes do not permit the use of
cord connections, a 120 V, 50/60 Hz
power supply, with suitable disconnecting
means, must be connected to the black
and white leads in the heater control
enclosure.
A knock-out hole is provided to permit use
of conduit or metal-clad cable connectors.
PRESSURE
SWITCH
TEMPERATURE
SWITCH
3 x 2 CONNECTOR
The maximum current draw is
approximately 5.0 amps.
The water heater must be electrically
grounded in accordance with local codes,
or, in the absence of local codes, in
accordance with latest edition of the
National Electric Code ANSI/NFPA No. 70.
Refer to pictorial below for water heater
internal wiring.
NOTE: It is not recommended that this
unit be installed on a GFCI circuit.
H
BK = BLACK
BL = BLUE
G = GREEN
R = RED
W = WHITE
Y = YELLOW
BL
5
R
4
Y
3
W
2
BK
1
G
TS1
BK
1
2
3
BK
TS2
W
1
2
FV
W
1
SPARK
H
SCHEMATIC
<
120 VAC
P1
1
2
3
4
5
TS1
P3
1
2
3
TS2
FV
P2
1
2
E1
1
PILOT
ELECTRODE
GND
ASSY
120
N
>
MOT
PS
TS
N
17