Exhaust Information; Wire Connection - GE GTDL310EMWS Installation Instructions Manual

Ge long vent 7.0 cu. ft. duradrum electric dryer
Table of Contents

Advertisement

CONNECTING DRYER USING 3-WIRE
CONNECTION
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
GREEN
OTHER ESTABLISHED GROUND
GROUND
DETERMINED BY A QUALIFIED
SCREW
ELECTRICIAN.
SCREWS
(3)
COVER

3-wire Connection

WARNING:
COVER OFF OF THE TERMINAL BLOCK.
Installation Instructions
GROUND
STRAP
HOT
STRAIN RELIEF
WIRE
BRACKET
L 1
3/4", UL
RECOGNIZED
L 2
STRAIN RELIEF
NEUTRAL
HOT
(White)
WIRE
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
NEVER LEAVE THE

EXHAUST INFORMATION

3
WARNING -
UNITED STATES, THE REQUIRED EXHAUST
DUCT DIAMETER IS 4 in (102mm). DO NOT USE
DUCT LONGER THAN SPECIFIED IN THE EX-
HAUST LENGTH TABLE.
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect installation
are not covered by the warranty.
MAXIMUM ALLOWABLE
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Recommended
4" DIA.
4"
No. of 90°
Rigid
Elbows
Metal
0
150 Feet
1
135 Feet
2
125 Feet
3
115 Feet
4
105 Feet
5
95 Feet
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
SEPARATION OF TURNS
TURNS OTHER THAN 90º
IN CANADA AND IN THE
Exhaust Hood Types
Use only for short
run installations
4" DIA.
4" DIA.
2-1/2"
Rigid
Metal
125 Feet
115 Feet
105 Feet
95 Feet
85 Feet
75 Feet