BEFORE YOU BEGIN

Read these instructions completely and
carefully.
IMPORTANT-
Save these instructions
for local inspector's use.
IMPORTANT-
Observe all
codes and ordinances.
• Note to Installer -
instructions with the customer.
• Note to Customer - Keep these instructions
with your Owner's Manual for future reference.
or discarded, remove the dryer door.
• Service information and the wiring diagram
are located in the control console.
• Do not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
• Install the dryer where the temperature is
dryer control system.
• Product failure due to improper installation is
not covered under the Warranty.
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
Step 1 Prepare the area and exhaust for installation of new dryer
Step 4 Move the dryer to the desired location.
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
• To reduce the risk of severe injury or death, follow all installation
• Install the clothes dryer according to these instructions and in
governing
• This dryer must be exhausted to the outdoors.
• Use only rigid metal 4" diameter ductwork inside the dryer cabinet and use
• Do not install or store this appliance in any location where it could be
NOTE: Installation and service of this dryer requires basic
mechanical and electrical skills. It is your responsibility to contact
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
WARNING
RISK OF FIRE
instructions.
accordance with local codes.
only UL approved transition ducting between the dryer and the home duct.
and installed in accordance with the instructions found in "Connecting
materials are known to collapse, be easily crushed, and trap lint. These
exposed to water and or weather.
MATERIALS YOU WILL NEED
4" DUCT
4" DIA. METAL
CLAMPS (2)
ELBOW
OR
4" SPRING
CLAMPS (2)
DUCT TAPE
4" COVER PLATE (IF NEEDED
(KIT WE1M454)
Step 8 Check the operation of the power supply and venting.
Step 9 Place the Owner's Manual and the Installation Instructions
in a location where they will be noticed by the owner.

Electric Dryer

04
SAFETY
EXHAUST
GLASSES
HOOD
3/4" STRAIN
RELIEF
GLOVES
UL RECOGNIZED
234D2004P004 31-16309 03-13 GE
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.

Advertisement

Table of Contents
loading

Summary of Contents for GE GTDL210EDWW

  • Page 1: Electric Dryer

    Installation Electric Dryer Instructions Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN WARNING RISK OF FIRE Read these instructions completely and • To reduce the risk of severe injury or death, follow all installation carefully.
  • Page 2: Electrical Requirements

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation must be given to provide adequate clearance for installation and service. CONNECTING DRYER USING 4-WIRE PREPARING FOR INSTALLATION OF CONNECTION (MUST BE USED FOR NEW DRYER MOBILE HOME INSTALLATION) TIP: Install your dryer before installing your washer. This NOTE: Since January 1,1996, the National Electric code will allow better access when installing dryer exhaust.
  • Page 3 Installation Instructions CONNECTING DRYER USING 3-WIRE EXHAUST INFORMATIO CONNECTION WARNING - IN CANADA AND IN THE If required, by local code, install external UNITED STATES, THE REQUIRED EXHAUST DUCT cold water pipe, or other established DIAMETER IS 4 in (102mm). DO NOT USE DUCT ground determined by a qualified LONGER THAN SPECIFIED IN THE EXHAUST electrician.
  • Page 4: Exhaust Connection

    Installation Instructions SEALING OF JOINTS STANDARD REAR EXHAUST STANDARD REAR EXHAUST • All joints should be tight to avoid leaks. The male end of (Vented at floor level) each section of duct must point away from the dryer. • The duct shall not be assembled with screws or other FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO fastening means that extend into the duct and catch lint.
  • Page 5: Alcove Or Closet Installation

    Installation Instructions For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe. 2. Secure the duct with a clamp. without kinking and or crushing the transition duct, 3. With the dryer in its permanent position, extend the duct to its full length.
  • Page 6 Installation Instructions BATHROOM OR BEDROOM INSTALLATION FIXING HOLE • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL 9" Cut the duct as shown and keep portion A. MOBILE OR MANUFACTURED HOME TAB LOCATION INSTALLATION BEND TAB...
  • Page 7 Installation Instructions ADDING COVER PLATE TO REAR OF ADDING ELBOW AND DUCT FOR CABINET (SIDES AND BOTTOM EXHAUST) EXHAUST TO RIGHT SIDE OF CABINET • Preassemble 4” elbow with 4” duct. Wrap duct tape around joint. opening and connect the elbow to the dryer internal duct.
  • Page 8 Installation Instructions SERVICING REGISTER YOUR NEW APPLIANCE TO RECEIVE ANY WARNING - LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING Please go to www.GEAppliances.com or mail in CONTROLS. WIRING ERRORS CAN CAUSE your product registration card. IMPROPER AND DANGEROUS OPERATION AFTER SERVICING/INSTALLATION.

Table of Contents