Page 3
DS7400Xi Panel Wiring & Programming Before servicing, remove all power including the transformer, battery and phone line. A complete functional test is required after any programming. Incorrect connections may result in damage to the unit. System is Power Limited except for battery terminals.
Page 4
DS7400Xi Panel Wiring & Programming A/C Power Indication LED EARTH GROUND Must be connected to a good earth ground such as a cold water pipe and also connected to the cabinet cover using the supplied wire jumper. A/C INPUT: Use U.L. listed, 18 VAC 50 VA, class 2 transformer.
Page 5
DS7400Xi Panel Wiring & Programming OPTIONS BUS: Used for options such as the ARDIS communications module, the DS7420i Dual Phone Line module, etc. Also for keypads #11 - #15. For Commercial Fire Mode: Option Bus Wiring must be run in conduit if run outside the enclosure.
Page 6
DS7400Xi Panel Wiring & Programming = Maximum wire length each: 1000 ft. (305 m). Max. wire length total in system: 6000 ft. (1830 m) when using #22 AWG (.8mm) or #18 AWG (1.0mm) KEYPAD BUS*: cable. Up to 15 keypads** may be used.
Page 8
DS7400Xi Panel Wiring & Programming PROGRAMMABLE OUTPUTS: PO1 shorts to aux. power negative when activated. PO1 can sink up to 1.0A. PO1 function programmed in address 0147. PO2 supplies 12 V and up to 500 mA when activated. PO2 function programmed in address 0148.
Page 9
DS7400Xi Panel Wiring & Programming Wiring & Programming for Installations using Ademco AB-12 Housing Disconnect wire jumper from terminal 4 to inner housing of Bell Box. (Prevents a ground fault condition) Connect wiring between control and Bell Box as shown next slide.
Page 10
DS7400Xi Panel Wiring & Programming Cut this Jumper - JP1 Outer Bell Housing Inner Bell Housing Control/Communicator To Earth Ground Terminal 1 To Control Loop Positive Terminal 29 To Control Zone 8 Input Terminal 30 27kW To Control Alarm Output Terminal 5...
Page 16
DS7400Xi Panel Wiring & Programming Using the Reference Guide Sections The Cover - Keypad Quick Reference Specifications Enclosure Installation & Terminal Wiring Quick Start Guide System Worksheet - Helps with system planning System Overview/Glossary - Explains most important terms Operating Guide Programming U.L.
Page 17
DS7400Xi Panel Wiring & Programming DS7400Xi Version 3.04 Fire Walk Test (V3.04) Revision 3.04 incorporates a “Fire Walk Test” to allow the manual testing of all fire zones in the panel. Two reports -- “Fire Walk Test” and “Fire Walk Test Restore”...
Page 18
DS7400Xi Panel Wiring & Programming DS7400Xi Version 3.04 Multiplex Smoke Detectors (V3.04) The DS7400Xi has the capacity to use Detection Systems MX280 Series Multiplex Smoke Detectors. These Low Profile Smoke Detectors mount directly to the Multiplex Bus and have the ability to self monitor the sensitivity of the detector using the ChamberCheck feature.
Page 19
ROM Size Change (V3.03) Revision 3.03 and higher of the DS7400Xi now uses a 32-pin ROM. The board revision required for this ROM is 29230F. Controls manufactured prior to the introduction of the 32 pin socket included a 28 pin socket.
Page 20
DS7400Xi Panel Wiring & Programming LED Keypads Zone Display (V3.03) The LED keypads were only displaying the lowest numbered zone when multiple zones were faulted. LED keypads now properly display all faulted zones (for which an LED exists). LED keypads will still only display zones 1 through 8 (for DS7445) or 1 through 6 (for DS7443).
Page 21
DS7400Xi Panel Wiring & Programming Duress PIN Operation (V3.03) When using the Duress PIN to disarm a partition when in single partition mode on a master keypad, the user is able to toggle through all partitions using # - #.
Page 22
DS7400Xi Panel Wiring & Programming “Not Ready” Display Changes (V3.02) The “Not Ready” display indicates the number of the violated zone in all cases except for Invisible zones. Invisible zones that are violated do not display until a PIN + OFF sequence is entered.
Page 24
DS7400Xi Panel Wiring & Programming Addressing a Multiplex Sensor Must be done prior to installation of the device Program Zone. Address 0026-0145 must be programmed before addressing sensor. Disconnect the multiplex bus. Only one device (the one being addressed) should be connected to the bus at this time...
Page 25
DS7400Xi Panel Wiring & Programming Addressing a Multiplex Sensor D5060 Multiplex Point Programmer Handheld programming tool. Programs DS point modules, contacts, multiplex motion detectors. Take the D5060 to the point. Powered by two 9VDC batteries. [Approximately 12 hours of use.] Can also be powered by 16.5VAC transformer.
Page 28
DS7400Xi Panel Wiring & Programming Multiplex Point Programmer Displays and Meanings Display Meaning Enter Address A.dr Enter Address for Interrogation Mode Battery Voltage is below 15 volts Point was not programmed correctly Battery Voltage is below 16 volts No Response from Point...
Page 29
DS7400Xi Panel Wiring & Programming WDSRP Remote Programmer Windows Detection Systems Remote Programmer Unattended Capability One program for all DS controls Windows 3.1 or Windows 95 Multiple Sessions Up to 4 phone lines at once See separate Powerpoint Presentation: “Windows Detection Systems Remote Programming”...
Page 30
DS7400Xi Panel Wiring & Programming How to connect to WDSRP Manual call - Someone on site Call the panel location from a phone connected to the computer Once connection to location completed, press MANUAL at WDSRP. Wait for carrier tone then press...
DS7400Xi Panel Wiring & Programming Programming From the Keypad Enter the program mode Default password is 9876 # 0 -or- Short Program Pads 4 digit Program Address (always) 2 digit value (usually) Current Panel ROM Prog. Mode 3.04 Adr.=0000 D01=2...
Page 32
DS7400Xi Panel Wiring & Programming Programming From the Keypad enter data: Enter the address Enter the Value Prog. Mode 3.04 Adr.=0000 D01=2 Press the to accept read data: Enter the address Press the Continue with through addresses Tip: Programming mode will automatically scroll to next address.
Page 33
DS7400Xi Panel Wiring & Programming Programming From the Keypad If you wish to program a different address, press the key two times and enter the program address you wish to program. If you make a mistake at any time, press the key two times before pressing key.
Page 34
DS7400Xi Panel Wiring & Programming Programming From the Keypad Entering Hexadecimal Characters Used when entering values greater than “9” Press then 0 - 5 ( = a value of 10) Hex characters values are: 0 = A 1 = B...
Page 35
Programming From the Keypad Feature 1 Feature 2 Defaults Feature 3 The DS7400Xi is shipped from the factory as a working, pre-programmed control. Many of the programming addresses may already be set to the values you need. The default values are shown in...
Page 36
DS7400Xi Panel Wiring & Programming 1 2 3 4 5 6 Programming From the Keypad Feature 1 Feature 2 Setting the Control to the Factory Default Feature 3 Entering [0] [1] [#] in Program Address 4058 will immediately reset the control to the factory default.
Page 37
DS7400Xi Panel Wiring & Programming Programming From the Keypad Understanding the Programming Charts The Programming Reference Guide makes use of three types of charts. If the chart looks like this, a combination of features is available to be programmed for that particular address.
Page 38
DS7400Xi Panel Wiring & Programming Programming From the Keypad If the chart looks like this, only a single feature is available to be programmed for that particular address. Select Option Disabled Perimeter Instant Identifies options/features 24-Hour available for this address Entry/Exit Delay #1 To select “Entry/Exit Delay #2,...
Page 39
DS7400Xi Panel Wiring & Programming General Control Programming: Prog Address 0000 Data Digit Enter the Data Digit as a: 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5 Select Options Allow Normal and Custom Arming **...
Page 40
DS7400Xi Panel Wiring & Programming General Control Programming: Address 0000 Enter DD as a: 0 1 2 Select Options Restore zone when Sounders Silence Previous Restore zone when Zone Restores Slide, Digit 2 Restore zone when System is Disarmed Allow Swinger Shunts...
Page 41
DS7400Xi Panel Wiring & Programming Programming A Zone Programming a zone is a 3 step process. Step 1 is programming zone functions (what a zone will do in alarm). Step 2 is assigning a zone function to the zone. Step 3 is to assign the zone to a partition.
Page 42
DS7400Xi Panel Wiring & Programming Programming Address 0001-0015 5 are Hex values. They will display as C-F at keypads. Data Digit Enter the Data Digit as a: 1 2 3 4 5 6 7 *2 *3 *4 *5 Select Options...
Page 43
DS7400Xi Panel Wiring & Programming Addresses 0001-0015: Select Option Zone Functions Disabled Data Digit Perimeter Instant Note: 24-Hour If Digit 2 = 9, use this Entry/Exit Delay #1 chart to select Digit 1 Entry/Exit Delay #2 Interior Entry/Exit Follower Interior Home/Away...
Page 44
DS7400Xi Panel Wiring & Programming Programming A Zone Default Values Value Zone Address (Will be forced to different values when in (Fill in) Function Commercial Fire Mode. See Sec 11.15.3) 0001 2 = Steady Alarm Output, alarm on short & open...
Page 45
DS7400Xi Panel Wiring & Programming Programming A Zone Default Values Value Zone Address (Will be forced to different values when in (Fill in) Function Commercial Fire Mode. See Sec 11.15.3) 0009 0 = ___________________________________ 0 = Disabled 0010 0 = ___________________________________...
Page 46
DS7400Xi Panel Wiring & Programming Program Address 0001-0015 Zone Functions Exercise: Program a custom zone function as follows: Zone Function 9 Steady Alarm Alarm on Short Alarm on Open Entry/Exit Delay Cancel 1 0 0 0 9 Program Address: ___ ___ ___ ___...
Page 48
DS7400Xi Panel Wiring & Programming Programming Zones: Select Option Single Zone Input Data Digit 1 [Zns 1-8, mux contacts, sensors, or DS7457) Multiple Zone Input [Any Zone on a DS7432, DS7433, or DS7460) DS7465 Connections Input Zn or Output Relay For input [odd-numbered] zns, use Zone Function value.
Page 49
DS7400Xi Panel Wiring & Programming Programming Zones: Data Digit 1 MX280, MX280TH Multiplex Smoke Detectors For Mux Smoke Detector zones, use a Zone Function programmed Data Digit 2 as a Fire Zone [with or without verification] with Trouble on Open...
Page 50
DS7400Xi Panel Wiring & Programming Zone ZoneFunction Descriptions Zone Funct. Address [Default values shown will differ if changed in Function Zone Function Programming.] Value 0001 Steady Alarm Output, alarm on short & open Entry/Exit Delay 1 0002 Steady Alarm Output, alarm on short & open...
Page 53
DS7400Xi Panel Wiring & Programming Step 3:Programming Zone Partition Assignments Addresses 1248-1311 Data Digit Select Option Belongs to Partition 1 Belongs to Partition 2 Odd-numbered zones Belongs to Partition 3 Belongs to Partition 4 Belongs to Partition 5 Even-numbered zones...
Page 54
DS7400Xi Panel Wiring & Programming Zone Function Bypass Programming Data Digit Program Address 0016 Enter the Data Digit as a: 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5 Select Options Zone Function 1 Can Be Bypassed...
Page 55
DS7400Xi Panel Wiring & Programming Zone Function Bypass Programming Data Digit Program Address 0017 Enter the Data Digit as a: 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5 Select Options Zone Function 9 Can Be Bypassed...
Page 56
DS7400Xi Panel Wiring & Programming Output Programming: Addresses 0146-0148 Data Digit Select Option Latch on ANY Zone Alarm [incl Invisible] ON During Entry Pre-Alert ON for 10 sec. After pressing [System Reset] ON When System is Armed Ground Start System Status (Ready to Arm)
Page 58
DS7400Xi Panel Wiring & Programming Output Partition Assignment PA0149 PA0150 Output Address Default Alarm 0149-DD1 Data Digit Data Digit Programmable Output 1 0149-DD2 Programmable Output 2 0150-DD1 Select Option Belongs to Partition 1 Belongs to Partition 2 Belongs to Partition 3...
Page 59
DS7400Xi Panel Wiring & Programming Partition Control Programming PA 0165 Data Digit Select Option Use 1 Partition Use 2 Partitions Use 3 Partitions Select Option Use 4 Partitions Use 5 Partitions No Common Area Partition 1 Common to Part. 2 & 3 Use 6 Partitions Partition 1 Common to Part.
Page 60
DS7400Xi Panel Wiring & Programming PA 0173 PA 0174 PA 0175 PA 0176 Data Digit DD 1 DD2 DD1 DD2 DD1 DD2 DD1 DD2 Keypad # PA 0177 PA 0178 PA 0179 PA 0180 DD 1 DD2 DD1 DD2 DD1 DD2...
Page 61
DS7400Xi Panel Wiring & Programming PA 0208 PA 0209 PA 0210 PA 0211 Keypad DD 1 DD2 DD1 DD2 DD1 DD2 DD1 DD2 Partition Keypad # Assignment PA 0212 PA 0213 PA 0214 PA 0215 DD 1 DD2 DD1 DD2...
Page 62
DS7400Xi Panel Wiring & Programming PA 0181 A-B-C Key Programming Data Digit Select Option Fire Key = Disabled Fire Key = Disabled Fire Key = Steady Alarm Fire Key = Pulsed Alarm Select Option Select Option Special Emergency Key = Disabled...
Page 63
DS7400Xi Panel Wiring & Programming Custom Arming Programming: Data Digit PIN + # 4 Arming Program Address 0183 Enter the Data Digit as a: 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5 Select Options...
Page 64
DS7400Xi Panel Wiring & Programming Custom Arming Programming: Data Digit PIN + # 4 Arming Program Address 0184 Enter the Data Digit as a: 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5 Select Options...
Page 65
DS7400Xi Panel Wiring & Programming PA0185 Force Arming & Ground Fault Programming Data Digit Select Option Do not allow Force Arming Allow up to 1 zone to be Force Armed Allow up to 2 zones to be Force Armed Allow up to 3 zones to be Force Armed...
Page 66
DS7400Xi Panel Wiring & Programming Commercial Fire Mode Programming PA 0186 Data Digit Enter the Data Digit as a: Select Options 1 2 3 4 5 6 7 8 9 *0 *1 *2 Commercial Fire Mode disabled Local Comm. Fire Mode enabled CentrStaComm.FireMode enabled...
Page 67
DS7400Xi Panel Wiring & Programming Commercial Fire Mode Programming PA 0186 Data Digit 1 on Previous Slide Enter Data Digit as: Select Options Bell and Aux activate on Fire Bell and Aux activate on Burg Pulsing Fire Alarms = 1 sec on, 1 sec off...
Page 68
DS7400Xi Panel Wiring & Programming PA 0187 Open/Close Report Control Programming Data Digit Enter the Data Digit as a: Select Options 0 1 2 3 4 5 6 7 Do not report opens or closes Report opens and closes in Partition 1...
Page 69
DS7400Xi Panel Wiring & Programming PA 0189 Open/Close & Zone Report Programming Data Digit Select Option Alternate between both Phone Nbrs Report to Phone Number 1 Data Digit 1 is for Open Report to Phone Number 2 and Close Reports...
Page 70
DS7400Xi Panel Wiring & Programming PA 0190 Report Control Programming Data Digit Select Option Alternate between both Phone Nbrs Report to Phone Number 1 Data Digit 1 does not Report to Phone Number 2 include Open & Close Report to Phone Numbers 1 and 2 or Zone Reports Data Digit 2 must be 0.
DS7400Xi Panel Wiring & Programming PA 0191-0196 Timer Programming Bell Cutoff Times are programmed in One-Minute intervals, except that an entry of “99” produces a 30-second bell cutoff. Entry and Exit Delay Times are programmed in 5-second intervals, as follows: 01 = 5 sec.
Page 72
DS7400Xi Panel Wiring & Programming PA 0191-0196 Timer Programming Data Digit Data Digit Entry Delay Time 1 Entry Delay Time 2 Address 0191 Address 0192 0 to 51 5-sec.) 0 to 51 5-sec.) Data Digit Data Digit Exit Delay Time...
Page 73
DS7400Xi Panel Wiring & Programming PA 0197 A/C Fail Report Delay Programming Data Digit The A/C Fail Delay Times are programmed as Hexadecimal values. Example: Send only with next report 30 Minute Delay 60 Minute Delay We count 0-9 120 Minute Delay...
Page 74
DS7400Xi Panel Wiring & Programming PA 0198-0201 General Code “Arm Only” Programming PA 0198 PA 0199 PA 0200 PA 0201 Data Digit Data Digit Data Digit Data Digit Partitions 1-2 Partitions 3-4 Partitions 5-6 Partitions 7-8 Select Option General Code can Arm, Disarm, Bypass...
Page 75
DS7400Xi Panel Wiring & Programming PA 0202-0205 General Code “Arm Only” Programming PA 0202 PA 0203 PA 0204 PA 0205 Data Digit Data Digit Data Digit Data Digit Partitions 1-2 Partitions 3-4 Partitions 5-6 Partitions 7-8 Select Option No Keypad Sounder During Exit Delay...
DS7400Xi Panel Wiring & Programming PA 0207 DS7412 RS232 Interface Data Digit Configuration Programming Select Option 300 Baud Enter the Data Digit as: 1200 Baud Select Options 1 2 3 4 5 6 7 2400 Baud No Parity 4800 Baud...
Page 78
DS7400Xi Panel Wiring & Programming PA 0496-0526 Account Code Programming Each partition can be programmed with a separate account number each of two phone numbers [Phone #1 and Phone #2]. Each account number takes two addresses [4 Data Digits] -- first 2 digits the even-numbered address;...
Page 79
DS7400Xi Panel Wiring & Programming PA 0496-0526 Account Code Programming Data Digits Phone #1 Acct Code = PA 0496 ____ ____ ____ ____ Partition 1 Phone #2 Acct Code = PA 0498 ____ ____ ____ ____ Phone #1 Acct Code = PA 0500...
Page 80
DS7400Xi Panel Wiring & Programming PA 0496-0526 Account Code Programming Data Digits Phone #1 Acct Code = PA 0512 ____ ____ ____ ____ Partition 5 Phone #2 Acct Code = PA 0514 ____ ____ ____ ____ Phone #1 Acct Code = PA 0516...
Page 81
DS7400Xi Panel Wiring & Programming PA 0528 Phone Number General Control Programming These notes apply to the following 2 slides: - Only applicable when using the ARDIS option. - See Addresses 0494-0495: ARDIS routing. - Required on PBX systems. - Option limited to Single-Partition systems.
Page 82
DS7400Xi Panel Wiring & Programming PA 0528 Phone Number General Control Programming Data Digit Enter the Data Digit as a: Select Options 3 4 5 6 7 8 9 *0 *1 Enable remote progrmr call-back Dial pulse on all phone numbers...
Page 83
DS7400Xi Panel Wiring & Programming PA 0528 Phone Number General Control Programming Data Digit Data Digit 1 on Previous Slide Enter the Data Digit as a: Select Options 1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5...
Page 84
DS7400Xi Panel Wiring & Programming PA 0529-0530 Phone Number Format Programming Ph Nbr 1 Format = PA 0529 Data Digit Select Option Ph Nbr 2 Format = PA 0530 Phone Number Disabled 3/1 No Extended Reporting 3/1E (Extended Reporting) 3/1 with Parity...
Page 85
DS7400Xi Panel Wiring & Programming PA 0529-0530 Phone Number Format Programming Data Digit Data Digit 1 on Previous Slide Enter Data Digit as: Select Options 1900Hz Data/ 1400Hz Ack 1800Hz Data/ 2300Hz Ack BFSK, SIA, Contact ID 10 Pulses per second (PPS)
Page 86
DS7400Xi Panel Wiring & Programming PA 0531 Telephone Answering Machine Programming Data Digit 1 pertains to accessing panel by phone when armed. Data Digit 2 pertains to accessing panel by phone when disarmed. Odd numbered ring counts override the answering machine.
Page 87
DS7400Xi Panel Wiring & Programming When Armed PA 0531 Telephone Select Option Data Digit Answering Don’t Answer Phone Machine Answer Phone on 1 ring Programming Answer Phone on 2 rings Answer Phone on 3 rings Answer Phone on 4 rings...
Page 88
DS7400Xi Panel Wiring & Programming When Disarmed PA 0531 Telephone Select Option Data Digit Answering Don’t Answer Phone Machine Answer Phone on 1 ring Programming Answer Phone on 2 rings Answer Phone on 3 rings Answer Phone on 4 rings...
Page 92
DS7400Xi Panel Wiring & Programming PA1456-1471 Octal Relay Module Output Programming Select Option Data Digit Latch ON after Zone Alarm ON during Entry Pre-Alert ON for 10-sec after System Reset ON when System is Armed Ground Start System Status (Ready to Arm)
Page 93
DS7400Xi Panel Wiring & Programming PA1456-1471 Octal Relay Module Output Programming Select Option Data Digit Disabled *2 = Follow System AC Power Fail ……..Wide Events Low Battery Communication Failure Any System Fault Keypad Supervision Fault Multiplex Bus Fault 3 are Hex values.
Page 94
DS7400Xi Panel Wiring & Programming Select Option Octal Relay Module Disabled Output Programming Follow Output Function 1 Follow Output Function 2 PA1456-1471 Follow Output Function 3 Data Digit Follow Output Function 4 Follow Output Function 5 *3 = Follow Output ……...Functions...
Page 95
DS7400Xi Panel Wiring & Programming Output Function Programming PA 1472-1516 Each function could use up to 3 programming addresses. Eg.: Output Function 1 is programmed at PA 1472 - 1473 - 1474. Output Program Program Program Function # Address 1...
Page 96
DS7400Xi Panel Wiring & Programming Output Function Programming PA 1472-1516 Program Address 1: Data Digit 1 Option programs Output [latching] to follow Zone Alarm. Options thru program Output to follow system-wide status events. Options thru program Output to follow a single zone, or two zones in an Input/Output Cross Matrix.
Page 97
DS7400Xi Panel Wiring & Programming Select Option Output Function Latch ON after Zone Alarm Programming PA1472-1516 ON during Pre-Alert ON when system is armed Data Digit Program Address 1 Zone Alarm Zone Alarm delayed by 20-sec. Keypad Sounder Output Data Digit Access Output (10-sec.
Page 98
DS7400Xi Panel Wiring & Programming Select Option Output Function Follow System Status Event Programming PA1472-1516 Select Option Data Digit Program Address 1 AC Power Failure Low Battery Communication Failure System Fault (any) Keypad Supervision Fault Multiplex Bus Fault Radio Receiver Fault...
Page 99
DS7400Xi Panel Wiring & Programming Select Option Output Function Follow a single zone Programming PA1472-1516 Follow 2 zones if either changes Follow 2 zones if both change Data Digit Program Address 1 Enter the Data Digit as a: Activate: 0 1 2 3 4 5 6 7 8 9 *0 *1 *2...
Page 100
DS7400Xi Panel Wiring & Programming Output Function Programming PA 1472-1516 Previous 3 slides were about creating Program Address 2 Program Address 3 Program Address 1 Data Digit Data Digit Data Digit To create Enter the Zone Number of the First Zone to follow.
Need help?
Do you have a question about the DS7400Xi and is the answer not in the manual?
Questions and answers