4. TROUBLEShOOTING
4-7) Table of Set Point Shift Function
< Reference Bar Display Binary Table>
coDe
0
1
2
leD
x
x
x
Display on
x
x
x
Display on
x
x
x
Display on
x
x
x
Display on
x
x
x
Display on
x
x
o
Display on
x
o
x
Display on
coDe
19
20
21
leD
x
x
x
Display on
Display on
x
x
x
Display on
o
o
o
Display on
x
x
x
Display on
x
o
o
Display on
o
x
x
o
x
o
Display on
4-8) Set Point Shift Function
Press Freezer t emp. and energy Saver(Vacation) buttons simultaneously for 12 seconds to
●
get into this mode.
in this mode, only the display leDs for temperature will be on.
●
Press both buttons simultanequsly for 12 seconds
1) initially, the code is set to "0".
2) after 20 seconds from adjustment, a new setting will be stored in eePRoM and display will return to
normal.
3) Freezer temp, Fridge temp, ice maker water supply, ice tray temperature, can be adjusted with this
function.
3
4
5
6
7
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
o
x
o
o
o
o
x
o
x
x
o
o
x
o
x
o
x
o
x
22
23
24
25
26
27
x
x
x
x
x
x
x
x
x
x
x
x
o
o
o
o
o
o
x
o
o
o
o
o
o
o
x
x
x
x
o
o
x
x
o
o
x
o
x
o
x
o
39
9
10
11
12
13
14
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
o
o
o
o
o
o
x
x
x
o
o
o
x
o
o
x
x
o
o
x
o
x
o
x
28
29
30
31
32
33
x
x
x
x
x
x
x
x
x
x
o
o
o
o
o
o
x
x
o
o
o
o
x
x
o
o
o
o
x
x
x
x
o
o
x
x
x
o
x
o
x
o
15
16
17
18
x
x
x
x
x
x
x
x
x
o
o
o
o
x
x
x
o
x
x
x
o
x
x
o
o
x
o
x
34
35
36
x
x
x
o
o
o
x
x
x
x
x
x
x
x
o
o
o
x
x
o
x