Display Bbu Capacity; Display Bbu Capacity Information - IBM ServeRAID M5025 User Manual

Sas/sata controller
Hide thumbs Also See for ServeRAID M5025:
Table of Contents

Advertisement

Table 6.2
Display BBU Status Information
Description
Displays complete information about the BBU status, such as the temperature and
voltage. The information displays in the following formats:
BBU Status for Adapter: xx
Battery Type: XXXXXX(string)
Voltage: xx mV
Current: xx mA
Temperature: xx C°
Firmware Status: xx
Battery state: xx
Gas Gauge Status:
Fully Discharged: Yes/No
Fully Charged: Yes/No
Discharging: Yes/No
Initialized: Yes/No
Remaining Time Alarm: Yes/No
Remaining Capacity Alarm: Yes/No
Discharge Terminated: Yes/No
Over Temperature: Yes/No
Charging Terminated: Yes/No
Over Charged: Yes/No
Additional status information displays differently for iBBU™ and BBU.
For iBBU:
Relative State of Charge: xx
Charger System State: xx
Charger System Ctrl: xx
Charging Current: xx mA
Absolute State of Charge: xx%
Max Error: xx%
For BBU:
Relative State of Charge: xx
Charger Status: xx
Remaining Capacity: xx mAh
Full Charge Capacity: mAh
isSOHGood: Yes/No
6.1.2.3

Display BBU Capacity

Table 6.3

Display BBU Capacity Information

Convention
MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aN|-a0,1,2|-aALL
6-8
Use the command in
selected controller(s).
Using the Intelligent Battery Backup Unit
Table 6.3
to display the BBU capacity for the

Advertisement

Table of Contents
loading