Troubleshooting - Masalta ML42 Instruction Manual

Light tower
Table of Contents

Advertisement

MAINTENANCE

3.8 Troubleshooting

LIGHT Tower
SYMPTOM
POSSIBLE CAUSES
Lamp will not light
Lamp is too hot
Faulty lamp connection
Lamp broken or burned out
Circuit breaker turned on
Circuit breaker loose or
defective
Generator output incorrect
Low or no ballast output
Low light output
Lamp degraded
Low ballast output
Fixture or lens dirty
Unavailable to rise
The cable is stuck in the
tower
Steel wire rope goes out of
the winch
Hard to rise the tower
Tower goes down
The damage to the winch
after rising
The shaft of the winch is
loose
Tower can not be
The mast is lack of grease
lowered
MAINTENANCE RECORD
SOLUTION
Allow lamp to cool 10–15 minutes
before restarting.
Check that lamp is tight in socket.
Check connections inside connection
boxes on light fixtures and tower.
Check for:
broken arc tube or outer lamp jacket
broken or loose components in lamp envelope
blackening or deposits inside lamp tube.
Turn off circuit breaker.
Have a licensed electrician repair or replace the circuit
breaker.
Check incoming voltage to ballast. If voltage is incorrect,
engine speed may need to be adjusted or generator may
require service.
With the fixture cord removed from its receptacle, the
voltage should measure 400 to 445 VAC. If proper voltage
is not achieved, perform capacitor check to determine if
capacitor or coil needs to be replaced.
Replace lamp due to normal lamp life.
Check ballast for proper voltage output.
Clean reflective surface inside fixture
and both inside and outside surface of glass lens.
Pull out the cable
Fix the steel wire rope into the suitable position
Anointment to the friction surface of the mast
Change a new winch
Fasten the shaft
Anointment to the friction surface of the mast