  • Page 1 LTR50001131, Rev. A 1/2/13...
  • Page 2: Table Of Contents

    Preparing for Your New Portable Spa Ozonator . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Filter Cleaning .
  • Page 3 • Unconsciousness dizziness, lethargy, drowsiness and fainting. The WARNING: The use of alcohol, drugs, or medication effects of excessive hyperthermia may include: can greatly increase the risk of fatal hyperthermia. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 4 WARNING: Do not use a spa or hot tub immediately following strenuous exercise. WARNING: Prolonged immersion in a spa or hot tub may be injurious to your health. CAUTION: Maintain water chemistry in accordance with manufacturer’s instructions. SAVE THESE INSTRUCTIONS . Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 5: Preparing For Your New Portable Spa

    Consider the view of your neighbors as well when always best to design special installations so that the you plan the location of your spa. spa can still be moved, or lifted off the ground. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 6: Preparing A Good Foundation

    We strongly recommend that a qualified, licensed will weigh approximately 5,000 lbs, or 2267 kg, when contractor prepare the foundation for your spa. full of water. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 7: 240 Volt Electrical Installation

    Press the TEST button on the GFCI. The GFCI will trip and the spa will shut off. Reset the GFCI breaker by switching the breaker to the full OFF position, wait a moment, then turn the breaker back on. The spa should have power again. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 8: Gfci Wiring Diagram

    GFCI Wiring Diagram Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 9: Filling And Powering Up Your Portable Spa

    Never fill your spa with soft water. Soft water makes it impossible to maintain the proper water chemistry and may cause the water to foam, which will ultimately harm the finish of the spa and void your warranty. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 10 Put the cover on and let the spa run for two hours. Adjust water chemistry . After the spa has run for two hours, test and adjust the water chemistry. See the section on page 21 for instructions on water clarity. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 11: Priming The Pump

    When air is bled out, tighten the nut. Turn on power to the spa and press the JETS button. If there is still air trapped in the pump, repeat steps 2 through 5 until the pump primes. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 12: Operating Your Spa

    This is because the system requires after 4-5 minutes. Be sure that the pump(s) have approximately 1 minute of water flowing through been primed by this time. the heater to determine the water temperature and display it. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 13 Press the WARM and COOL buttons to change the hour. Press the LIGHT Press: button to adjust minutes. Setting the time of day is important for determining filtration times and other background features. 24-hour time display can be set under the PREF menu. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 14 Press the LIGHT button six times and the display will read HOLD. Press the WARM button again and the display will flash HOLDING FOR 0:60. When you are finished, press the LIGHT button to return to normal function. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 15 Press the LIGHT button six times and the display will read PREF. To toggle through the preferences, press the WARM button. Utilities This menu feature is for system information only and is used mainly for repair and troubleshooting. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 16 The ozonator will run with the circulation pump during their respective plumbing by running briefly at the filtration cycles. beginning of each filter cycle. Freeze Protection If the temperature sensors within the heater detect Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 17 There may not be enough water flow air, too many closed jets and pump through the heater to carry the heat prime. Heater start up will begin away from the heating element. again after about 1 minute. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 18 A Pump Appears To Be Stuck ON POWER DOWN THE SPA. DO NOT SRVC ---- ENTER THE WATER. Call for service. A pump appears to have been stuck ON when spa was last powered. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 19 Enter 255.255.0.0 for the Subnet Mask. Enter 169.254.1.1 for the Router. Touch the “Wi-Fi Networks” button at the top of the page to exit the screen. This address setup only has to be done once. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 20 The controls are visually oriented and require little explanation. Following are features you can control with the spa app. Temperature Set Time of Day Screen Main Controls Screen Screen Time of Day Screen Adjustment Settings Control Filter Cycle Set Screen Filter Cycle Time Filter Cycle Hour Screen Adjustment Adjustment Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 21: Electrical Power Efficiency

    Jets The jets in your spa are adjustable. Rotating the face of an adjustable jet will increase or decrease the amount of water flow through the jet. (See example shown below.) Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 22: Adjustable Therapy System

    • The green power light will flash to indicate Down reset. This button allows the user to cycle down through all seven massage modes, one at a time. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 23: Water Clarity

    Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 24: Testing And Adjusting Spa Water

    Need to raise the pH level surfaces. High pH can be corrected by adding a pH causes corrosion increaser Ideal Water Chemistry Testing For: Ideal Range (ppm) Minimum Maximum Total Alkalinity Calcium Hardness Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 25: Sanitation

    Follow the maintenance schedule on page 26. floater. Follow the maintenance schedule on page 26. Testing For: Ideal Range (ppm) Minimum Maximum Chlorine level Without ozonator With ozonator Bromine level Without ozonator 11.0 With ozonator 10.0 Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 26: Bather Load

    Cal Spas dealer for additional chemical or system recommendations. Be sure to give them your Recommendations are designed for spas with average bather load information. bather load (3 to 4 people, 15 minutes of usage, three Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 27: Pure Cure™ Water Sanitizer

    Set the spa’s filtration time four hours twice a day (described on page 11). This activates the ozonator and produces the ozone gas. Note: Filtration time may need to be increased with heavy bather load. Rejuvenation Series Spas LTR50001131, Rev. A...
  • Page 28: Maintenance Schedule

    We recommend that your spa water be changed every 4 to 6 months. You may find the need to change your spa water more frequently with heavy use. When empty, your spa should be cleaned with a non-abrasive cleaner and then rinsed thoroughly. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 29: Troubleshooting Water Clarity Problems

    Adjust total alkalinity and pH – if scale water – total alkalinity and requires removal, drain the spa, scrub off the pH too high scale, refill the spa and balance the water • Use a stain and scale inhibitor Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 30: Cleaning And Maintenance

    • Covering your spa helps prevent children from drowning in the spa. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 31: Draining Your Portable Spa

    Turn the valve on the hose-bib fixture to open the drain. Let spa drain completely, then remove garden hose. Turn the valve on the hose-bib fixture to close the drain. Replace the cap. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 32: Cleaning And Replacing The Filter

    Use a low detergent, non-abrasive cleaner specifically formulated to clean the spa without damaging its acrylic finish. Use a non-oil based surface protectant that is specifically formulated to protect the spa’s finish from the chemicals and minerals associated with normal spa use. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 33: Changing The Uv Lamp

    When replacement UV lamp has been installed, conduct a final leak check: Restore power to the spa at the GFCI. Turn on the pump and let water run for five minutes to check for leaks. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 34: Appendix

    The basic spa cover is designed with a tapered height, angling downward from four inches in the center to two-and-a-half inches on the sides to drive off rain and prevent water from pooling. Filled with 1 lb. foam. Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 35: Troubleshooting

    Clean filter cartridge Gate valves closed Open gate valves Spa cover improperly positioned Align spa cover Spa gets too hot Filtration time is set too long Reduce filtration cycles, especially during summer months Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 36 Jet spout opening missing Check jets and replace as necessary Light Problems Standard spa light does Light bulb has burned out Replace light bulb not work Lighting system is defective Contact your dealer Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 37 Motor overload will reset automatically. If problem persists, contact your dealer Damaged electrical cord Contact your dealer Pump cord not plugged in Plug pump cord into red receptacle GFCI tripped or in OFF position Reset GFCI Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 38: Limited Warranty

    Limited Warranty This limited warranty is effective for Rejuvenation Series spas manufactured after January 1, 2013 and is only valid on portable spas delivered in the United States and Canada. Cal Spas portable spas are warranted to be free from defects in material and workmanship. This warranty starts from date of manufacture and ends either by specified time-frame listed below, owner-transfer, relocation, or installation of any component other than by manufacturer.
  • Page 39 32˚F (0°C) to 118˚F understanding that the spa is not an essential device (47.8°C). or medical device as defined under State and Federal • Damage caused by incorrect water level (low, Rejuvenation Series Spas LTR50001131, Rev. A www.calspas.com...
  • Page 40: Warranty Registration

    This warranty only covers the Fountain of Youth of its representatives be held liable for injury to any Rejuvenation series spa. Spas sold as limited production person or damage to any property, however arising. models have their own warranties which are not covered in this manual.

This manual is also suitable for:

Rejuvenation fountain of youth

Table of Contents