On rare occasions while running in the AUTO mode with other zones activated there may
be an "E7" error code. "E7" error code occurs when 2 or more units are set to run in
different modes, such as HEAT and COOL. In the AUTO mode the unit automatically
switches between HEAT, COOL or FAN. If other zones are set to HEAT or COOL while the
AUTO is running in an opposite mode an "E7" will occur. To rectify this condition you must
set all the indoor units to the same mode, either HEAT or COOL, or leave the unit alone
and when the temperature returns to the point where the unit switches back to the correct
mode (as the other indoor units) and all zones are in the HEAT or COOL mode, it will clear
itself and begin to run again.
COOL mode – Unit cools room to set point temperature. Set point temperature can be set
from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures of +4 to +118 ºF in
the cooling mode. Indoor fan does not turn off in the cooling mode when temperature set
point has been satisfied. It will continue to run to keep the room temperature consistent.
HEAT mode (for Heat Pump units only) - Unit heats room to set point temperature. Set
point temperature can be set from 61 °F to 86 °F. Outdoor unit will operate in outside
temperatures of -5 ºF to +75 ºF in the heating mode. Indoor fan will turn off in heating mode
when temperature set point has been satisfied.
DRY mode – Set point temperature can be set from 61°F to 86°F. Unit cools at 90%
capacity while the FAN runs in LOW speed only (FAN speed cannot be changed).
FAN mode – Selects fan only operation. Set point temperature can be set from 61 °F to
86 °F. Fan speed can be set to AUTO, HIGH, MEDIUM or LOW.
FAN – Press this button to change fan speeds, Auto, Low, Low-Medium, Medium, Medium-
High, or High, while in the HEAT, COOL, FAN modes. When in the AUTO setting, the fan will run
faster the further away from the set point it gets. On the other hand the closer it gets to the set point
the slower it will run
Auto
Low speed
SWING – Pressing the SWING button slowly, (more than 2 seconds) will start and stop the
louver moving up and down. If the button is pressed to turn on swing and then pressed again to turn
it off, the louvers will remain in that fixed position until it is turned on again.
Pressing the button quickly, (less than 2 seconds) will step through 5
different stationary positions and then on to 3 different swing positions,
similar to the ICONS.
If any position
or
position as
that the louvers swing continuous.
Icons are for representation purposes only. Actual positions may vary.
Right to left louvers can be manually adjusted. CAUTION: Before adjusting the horizontal louvers
turn the unit off. Make the adjustments. Turn the unit back on. This will prevent possible personal
injury and or damage to the unit.
FOLLOW ME - Press this button, the room temperature sensor is by the remote control. Press
this button again and the room temperature sensor will be in the indoor unit.
&
ICON - Press the left blank button will illuminate
no affect with the units. Press the button again,
have no affect with the units.
950-0205revC
Low-Medium speed
Medium-High speed
is selected, the unit will carry out the
- 8 -
Medium speed
High speed
OFF
icon in the remote display but will have
icon will illuminate in the remote display but will
July 22, 2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smzc12h4zigxSmzc18h4zigx243-6001-e243-6002-e243-6003-e

Table of Contents