Sea Breeze SMZC9H4ZIGX User Manual page 16

Indoor console unit heat pump models
Hide thumbs Also See for SMZC9H4ZIGX:
Table of Contents

Advertisement

B o tto m fr a me
Ca si n g
Ca si n g
Re mo ve th e p i l l a r
Re mo ve th e p i l l a r
Figure 9b
.
Installation
● Secure using 6 screws of floor installations. (Do not forget to secure to the rear wall.)
● For wall installations, secure the mounting plate using 5 screws and the indoor unit using 4
screws.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1. Temporarily secure the mounting plate to the wall, make sure that the panel is completely level,
and mark the boring points on the wall.
2. Secure the mounting plate to the wall with screws.
Floor Installation
Wall Installation
Ca si n g
Molding
6 scr e ws
6 scr e ws
Figure 10
.
Flaring the pipe end
Cut the pipe end with a pipe cutter.
1. Remove burrs with the cut surface facing downward so that the chips do not enter the pipe.
2. Fit the flare nut on the pipe.
3. Flare the pipe.
4. Check flaring is properly done.
CAUTION!
Don not use mineral oil on flare part. Prevent mineral oil from getting into the system as this would
reduce the lifetime of the unit.
● Never use piping which had been used for previous installations.
● Never install a drier to this R410A unit in order to guarantee the lifetime.
● Poor flaring may cause refrigerant gas leakage.
950-0205revC
- 16 -
July 22, 2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smzc12h4zigxSmzc18h4zigx243-6001-e243-6002-e243-6003-e