CONNECTING TO GAS SUPPLY

This appliance is designed for running off the following types of gas at the corresponding operating pressures. The gas
category (or categories) of the appliance is given on the specifications label affixed to the appliance.
CATEGORY AND COUNTRY OF DESTINATION
MO8801D - MO8801S - MO8821D
MO8302 - MO8322 - MO8342
MO8362 - MO9202D - MO9202S
PI8002 - PI8022 - PI8042 - PI8062
PI8502 - PI8522 - PI8542 - PI8562
PI8802D - PI8802S - PI8822D - PI8822S
PI8842D - PI8842S - PI8862D - PI8862S
8203 - 8203 M - 8223 - 8223 M
MO8303 - MO8323 - PI9003 - PI9023
PI7203 - PI7223 - PI7703 - PI7723
PI8003 - PI8023 - PI8043 - PI8063
PI8403 - PI8423 - PI8443 - PI8463
PI8503 - PI8523 - PI8543 - PI8563
CHECK THESE SPECIFICATIONS BEFORE CONNECTING THE APPLIANCE TO THE
GAS CYLINDER /BOTTLE. THE PRESSURE REGULATORS CONNECTED BETWEEN
THE GAS CYLINDER AND APPLIANCE MUST CONFORM WITH THE CATEGORIES
GIVEN IN THE TABLE BELOW.
I3B/P(30)
AT BE DK FI DE GB NL NO SE CH SI
I3+ (28-30/37)
BE FR IE IT ES CH GB PT SI
MODEL
MO8821S - PI8621A
PI8621S
PI8621R
MO9222D - MO9222S
MO9122
7003 - 7023 - 7103 - 7123
8103 VD - 8103 VDM
8123 VD - 8123 VDM
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butane (G30)
37 mbar Propane (G31)
TOTAL NOMINAL THERMAL
CAPACITY
kW - gr/h
1,0 - 73
1,8 - 131
2,2 - 160
2,8 - 204
3,2 - 233
3,6 - 262
3,8 - 277
4,6 - 335
AIR VOLUME REQUIRED FOR
COMBUSTION
m
3
/h
2,0
3,6
4,4
5,6
6,4
7,2
7,6
9,2