3 Installation

3.1 Notes On Installation

NOTICE:
It is the installer's responsibility that the appliance is installed
according to the manufacturer's installation instructions, this
accessory manual, as well as national, state, and local code.
CAUTION:
The location and orientation of the vent termination must
follow those stated in the appliance Installation Manual. When
redirecting the flue discharge ensure it does not create a
hazard or nuisance.
NOTICE:
The concentric vent kit is approved for zero (0", 0 mm)
clearance to combustibles.
NOTICE:
This vent system is ULC-S636 certified for Canada.
DANGER:
Ensure the termination is installed at least 12" (300 mm)
f
above the average snow line. If this is not feasible, this
termination can not be used.
Needed Tools:
- Hole saw
- Tape measure
- Phillips screw driver
- Drinking water (as lubricant for gaskets)
- Weatherproof caulk
Bosch Thermotechnology Corp.
1
Fi
g. 2
Fig. 2 Legend:
1 Termination
2 Direction of flue discharge
3 Plume deflector
Concentric Horizontal Vent Kit | 7
2
3
Data subject to change