1.1 Key To Symbols 1.2 Safety Instructions 2 Scope Of Delivery 3 Installation 3.1 Notes On Installation 3.2 Appliance Adapter 3.3 Elbow and Wall Termination 3.4 Redirecting The Vent Discharge 4 Spare Parts Bosch Thermotechnology Corp. Data subject to change...
Never close off or reduce the size of the air intake and outlet openings. The appliance must not be operated until any obstructions have been removed. Inform the system operator in writing of the problem and the associated dangers. Data subject to change Bosch Thermotechnology Corp.
Page 5
Keep the combustion air free of corrosive substances The concentric horizontal vent terminal is intended for (halogenated hydrocarbons that contain chlorine or installation only with the Bosch Greenstar and Bosch fluorine compounds). Greenstar combi boilers (hereafter referred to as "appliance"):...
If this is not feasible, this termination can not be used. Needed Tools: - Hole saw - Tape measure - Phillips screw driver - Drinking water (as lubricant for gaskets) - Weatherproof caulk Bosch Thermotechnology Corp. Data subject to change...
[2]. 13³/₁₆" - 20⅞"(335 - 530mm) Fig. 5 Installing elbow While the screws are not fully tightened, the appliance Fig. 7 adapter can be swivelled around its vertical axis. Data subject to change Bosch Thermotechnology Corp.
Page 9
Fig. 8 Position terminal [1] from the outside through the vent opening so rubber thimble [2] is flush against outside wall . Slide the inner wall seal [3] onto the terminal [1] as shown. Bosch Thermotechnology Corp. Data subject to change...
Rotate the terminal end [B] 180° so discharge faces upwards. Refit the terminal end [B] and tighten the screws [A]. 180° Fig. 12 The entire termination can now be rotated left or right ±40° to redirect the plume ( Fig. 13). Data subject to change Bosch Thermotechnology Corp.