POST-SERVICE PRECAUTIONS

Initializing this Unit

Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the
PCB.
1. Press the power operation button to turn off the power, and remove the AC plug from the socket.
Insert the AC plug while pressing buttons "INPUT" and "BACK" together, and wait for more than 3
seconds.
3. Release buttons "INPUT" and "BACK" when the power indicator turns green.
4. All lights on the display illuminate for 2 seconds. The power indicator lights up in orange.
5. All lights on the display turn off for 2 seconds.
6. "Factory Reset" is shown on the display for 5 seconds.
The settings for the Installer Setup is also initialized.
Network function settings are not initialized.
NOTE: • If the unit fails to enter the service mode in step 6, repeat the procedure from step 1.
• Initializing the device restores the customized settings to the factory settings. Write down
your settings in advance and reconfigure the settings after initialization.
ENTER
BACK INPUT
Use network initialization mode to initialize the network related settings.
1. Press the power operation button to turn off the power, and remove the AC plug from the socket.
2. While the power is On, hold down buttons "POWER" for at least 3 seconds.
3. Release button "POWER" when the power indicator turns green.
4. Once "Special model" is displayed, press "CURSOR f ", select "Initialize" then press the "Enter"
button.
5. All lights on the display turn off for 5 seconds.
6. "Initialized" is shown on the display for 5 seconds.
•All settings, including network function settings, are initialized.
7. "Initialized" is displayed and the power turns off 90 seconds later.
(The network device is started and initialized during this time.)