Marantz NR1200 Service Manual page 99

Network audio receiver
Hide thumbs Also See for NR1200:
Table of Contents

Advertisement

When the results of check item (3-9.3.) are "00"
(Detection of HPD is not OK / Detection of RXSENSE is not OK )
Check the RXSENSE/HPD. (Monitor)
Check item(3-9.9.).
Checking the HPD and RXSENSE. :
Does the test point of RXSENSE close to the HDMI output terminal
[N1018] indicate the (3.3V)?
Does the voltage of HPD test point close to the HDMI output terminal
[N1018] indicate "Hi" (3-5V)?
N1018
HDMI
[OUT]
HPD
YES
NO
Check for a short circuit in the TMDS/HPD line.
If there is no problem, the HDMI Rx/Tx (U1027) is faulty.
Replace with a new device.
HDMI Rx/Tx [U1027] is faulty.
Replace with a new device.
Recheck from
check item (3.3.).
If it does not work, replace the PCB.
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents