Check the communication line.
YES
Check item(3-6.4.).
Check the communication line :
Check the CPU.
Is the waveform of the TP near the DIR [U1040] correct (like the one
shown in the diagram) when the power is turned on?
DR_CK 25pin
DR_DIN 24pin
DR_CE 26pin
DR_DOUT 23pin
U1040
YES
NO
Check item(3-6.5.).
Check the communication line :
Check DIR [U1040], CPU [U1013] patterns as well as soldering.
If there is no problem, go to the next step.
DIR [U1040] is faulty.
Replace with a new device.
Recheck from
check item (3.1.).
If it does not work, replace the PCB.
*The diagram shows an example.
(Signal patterns vary depending on the
timing.)
Points for checking waveforms
- Crest value (3.3V normally)
- Signal change
- CLOCK frequency (about 2MHz)
Voltage scale:2.0V/div
Time scale:2us/div