3. Starting detecting the point of failure
Check item(1).
Check the power supply status and communication status with the CPU of each device.
Start in HDMI Diagnostics mode and follow the procedures below.
(1) Start in HDMI Diagnostics mode
While the power is on, hold down buttons "M-DAX" and "DIMMER" for at least 3 seconds.
HDMI DIAGNOSTICS
"HDMI DIAGNOSTICS" is displayed.
When the mode has switched, start Hardware check.
Hardwarecheck...
(2-1) Display when an Error Code is displayed.
Err:
H1-XX
Alternating display.

Contact support

Check the Error Code table items.
Error Code table
Error Code
Check item No.
H1-01
Check item (5)
Communication Error with HDMI RX/Tx [U1027 : MN864788]
H1-02
Check item (10)
Communication Error with HDMI SW
H1-07
Check item (12)
Communication Error with OSD
H1-08
Check item (19)
Communication Error with DSP
H1-12
Check item (24)
Communication Error with DIR
H1-15
Check item (17)
Communication Error with OSD ROM
(2-2) Display when an Error is not detected.
Cancel the mode, and proceed to
Canceling the selected mode
Press the power button to exit off the power.
Description
[U1024 : MN864787]
[U1030 : ADV7623]
[U1021 : ADSP21487]
[U1040 : PCM9211]
[U1029 : MX25L3206EMI/MX25L6406EMI]