Download Print this page

Philips DVP3156 Service Manual page 13

Hide thumbs Also See for DVP3156:

Advertisement

All output voltages on the power board is 0V or deviated.
Check whether the components in the
short-circuit voltage are defected or eroded.
Great user manuals database on
All output voltages on
the power board is 0V or
deviated
Yes
Check whether
F1 is blown
No
Check
whether
there is 300V on C4.
Yes
Check whether 100KHz
oscillating
signal
on
Pin6 of U1
Yes
Check if +5V, +12V, -12V
and are short.
Yes
UserManuals.info
4-3
Remark: Trouble shooting chart for
Yes
Replace F1
No
Replace C4 if D1, D2, D3, D4
are normal.
No
Check/ replace U1.
U1(PIN 3 - RC waveform)
No
Check whether U2 are eroded.
Trouble shooting chart
DVP3160K/XX
U1(PIN 8 - Drain waveform)

Advertisement

loading