Using the Keypad
Normal operation:
To activate Relay1/Lock output, simply type in a valid code for that relay or press and release the free exit push button if one
has been installed:
-The relay will activate in the manner setup by the installer.
-The green LED indicator will activate as per the relay.
To activate Relay2/Aux output, simply type in the valid code for that relay or press and release the free exit push button if this
function has been configured and installed:
-The relay will activate in the manner setup by the installer.
-The yellow LED will activate as per the relay.
Alarm Monitoring Function:
If the alarm monitoring has been set up by the installer, and an alarm condition occurs, the following will happen;
• Alarm output activates,
• Built in buzzer sounds,
• Green LED begins flashing.
The follow alarm conditions are available:
• Door opened without a valid code entry first. (Door forced alarm)
• Door not closed by the time the Relay1/Lock output returns to standby status. (Door jammed open alarm)
• Keypad housing opened. (Tamper alarm)
After the alarm time (set by the installer) has expired, the alarm output and the built in buzzer resets. However, the
flashing green LED continues until the first valid user code is entered into the keypad. This way the user is made aware
that an alarm condition occurred even after the built in buzzer and alarm output have reset.

Bypass Function:

TO AVOID OVERHEATING OF THE SOLENOID, NEVER USE THIS FUNCTION WITH ELECTRO-MECHANICAL
STRIKERS or LOCKS!
In cases such as an office park or school gate automation, that needs to temporarily be kept open to allow for peak traffic
periods, this function can be used.
This function requires a dedicated code which is set up by the master code holder.
When the bypass code is entered, Relay 1/Lock output will latch on until either the same code is entered again or the free
exit push button is pressed.
While the bypass function is active, no other Relay 1/Lock output user code will release the relay.
This function is also useful where a magnetic lock is installed.