Installation and Test
I
NSTALLATION AND
Observe normal electrostatic discharge precautions when handling electronic equipment. Do
not hold electronic plug-ins by their edge. Do not touch components or circuitry.
I
NSTALLING THE
1
Insert the FRC-753 into the RT Enclosure and observe that all LEDs:
•
turn On for approximately two seconds
•
scan from top to bottom
•
turn Off
If the LEDs do not follow the above sequence, refer to
Use List 3 or higher PG-Flex CO and RT LUs when activating the ground start feature.
Provisioning the FRC-753
Provision the FRC-753 using the FLL-712 List 3 CO Line Unit practice. For each channel provisioned, select loop
start or ground start.
Verify Operation
Verify the following after the system is powered up and HDSL communication is synchronized:
1
Observe that the front panel Active indicators are all off and the Fault indicator is off (no calls are in progress).
2
Test circuits for loop start:
a
Place an outgoing call for each subscriber circuit provisioned and observe that the Active LED tracks the
progress of the call.
b
Place an incoming call for each subscriber circuit provisioned and observe that the Active LED tracks
the progress of the call.
3
Test circuits for ground start, circuits must be provisioned for ground start:
a
Place an outgoing call for each subscriber circuit provisioned and observe that the Active LED tracks the
progress of the call.
b
Place an incoming call for each subscriber circuit provisioned and observe that the Active LED tracks
the progress of the call.
6
T
EST
FRC-753
INTO THE
July 23, 1999
RT E
NCLOSURE
Table 1 on page
4.
363-753-142-01, Revision 01
FRC-753 List 4B