Align the H2TU-C-319 with the enclosure slot guides, then slide the unit in until it
touches the backplane card-edge connector. Push the H2TU-C into the slot guides
until properly seated in the card-edge connector.
P
OWER
When the H2TU-C powers up, the four-character display illuminates and reports
status messages.
If the H2TU-C is unable to communicate with the H2TU-R, it displays various alarm
and status messages. If the H2TU-C is able to communicate with the H2TU-R, the
following occurs:
1
The Status LED flashes red while acquiring the H2TU-R and turns a steady green
when the entire system is operating with no alarms. (The DS1 signal must be
present.)
The four-character display reports margin (SNR) readings (should be ≥ 6 dB) and
2
loop attenuation (should be <35 dB @196 KHz).
3
After the system powers up, alarm conditions that exist are reported on the
display. (The H2TU-C reports alarms if no DS1 signal is applied.)
P
ROVISIONING
After installing the H2TU-C, perform these basic provisioning tasks by accessing the
logon screen. Refer to the onscreen Help menu for navigational aids or use the
(to cycle through selections),
SPACEBAR
choice, or to display a menu),
directional arrow keys (to navigate to a menu or item).
1
Connect a maintenance terminal to the craft port (see front-panel illustration
inside), then press
2
Select the Config menu, Date and Time, then type the date and time.
3
Select the Inventory menu, then type in the unit ID numbers.
4
Change the settings of any system parameters, if necessary, by selecting the
Config menu, Standard Options or ADC Options. (Configuration options can
also be set from the front panel using the MODE and SEL pushbuttons. See the
"Front-Panel Configuration Options Using MODE and SEL"
5
Once the H2TU-C is successfully installed and provisioned, access the
Performance or Event Log menu to clear the Performance, Alarm History, or
Event Log screens, or use Master Clear in the Config menu.
-U
S
P
EQUENCE
or
ESC
CTRL
R
+
to refresh the logon screen, if necessary.
(to activate the current setting,
ENTER
F11
(to return to the parent menu), or
table inside.)
Þ
Continued