Electrical Box
Step
3
Pull out the indoor heat
exchanger thermistor.
4
Release the thermistor
harness from the pipes
of the heat exchanger
ASSY and from the
back slit at the top of
the electrical box.
5
Unfasten the 4 hooks
and remove the
electrical box cover.
6
Procedure
Indoor heat exchanger thermistor
Heat exchanger ASSY
Thermistor harness
Electrical box
(R21015)
Back slit
(R24256)
Electrical box
cover
Hook
Si041417EA
Points
Be careful not to lose the clip
of the thermistor.
Clip
(R11268)
The position of the indoor
heat exchanger thermistor
varies depending on the
model.
When reassembling, be sure
to insert the thermistor
harness in the back slit and
pass it below the pipes of the
heat exchanger ASSY as
shown in the picture.
Back slit
(R21079)
Thermistor harness
Hook
(R21017)
When reassembling, make
sure that the 4 hooks are
securely fastened.
Removal Procedure

Hide quick links: