Step
7
Detach the indoor unit
from the installation
plate.
2. Remove the indoor heat
exchanger.
1
Unfasten the 2 hooks
and remove the piping
fixture on the back of
the indoor unit.
2
Slightly pull out the
auxiliary piping.
3
Remove the 2 screws
on the left side and
unfasten the hook on
the rear side.
4
Unfasten the hook on
the right side and lift up
the indoor heat
exchanger.
Removal Procedure
Procedure
Back view
Piping fixture
Hook
Auxiliary piping
Hook
Indoor heat exchanger
Hook
Indoor Heat Exchanger
Points
(R21034)
(R24350)
(R21036)
(R21037)
When reassembling the
indoor heat exchanger,
make sure that the hook is
fastened.
(R21038)