Rs-232C Code Id Characters; Scanning Sequence; Scanning Sequence Example - Symbol LS 1004 Product Reference Manual

Table of Contents

Advertisement

RS-232C Code ID Characters

Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID
Characters listed in Table 4-3. These Code ID Characters are not programmable and are
separate from the Transmit Code ID feature. The Transmit Code ID feature should not be
enabled for these terminals.
UPC-A
UPC-E
EAN-8
EAN-13
Code 39
Codabar
Code 128
I 2 of 5
Code 93
D 2 of 5
UCC/EAN 128

Scanning Sequence

A scanning sequence establishes a value for one parameter type. During a scanning sequence,
bar codes are scanned to select a parameter. All bar codes necessary for programming the
scanner are provided in Parameter Menus, beginning on page 4-9.

Scanning Sequence Example

In this example, assume you want to program the scanner for all default settings except for
two parameters, DECODE UPC ONLY and INTERCHARACTER DELAY.
Since you want to keep the majority of the default settings, scan the SET ALL DEFAULTS bar
code. The default for DECODE UPC ONLY is DISABLED, but in this example, you need it
Table 4-3. Terminal Specific Code ID Characters
"A"
"E"
"FF"
"F"
"C" <len>
"N" <len>
"L" <len>
"I" <len>
None
"H" <len>
"L" <len>
ICL
FUJITSU
"A"
"E"
"FF"
"F"
None
None
None
None
None
None
None
Programming the LS 1004
NIXDORF
"A"
"C0"
"B"
"A"
"M"
"N"
"K"
"I"
"L"
"H"
"P"
4-7

Advertisement

Table of Contents
loading

Table of Contents