Siemens SCALANCE XM-400 Instructions Manual page 19

Configuring the virtual router redundancy protocol
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

3 Engineering VRRP
Assigning the IP address
The first assignment of an IP address for the SCALANCE cannot be done with
Web Based Management, because this configuration tool requires an IP address in
the first place.
There are several ways to assign an IP address to an unconfigured device:
SINEC PNI
PRONETA
STEP 7
DHCP
SINEC PNI
Industry Online Support.
Assign the planned IP address to the two SCALANCE routers with one of the
aforementioned tools:
Table 3-2
Device
SCALANCE XM408-8C
SCALANCE XM408-8C
Note
VRRPv3 supports IPv4 and IPv6. Both can be configured and operated
simultaneously with VRRPv3.
The following figures describe configuration with SINEC PNI.
1. Click "Start network scan".
2. Select the device found.
3. Click the "Device Management" button.
VRRP
Entry-ID: 109798556,
V1.0,
and
PRONETA
are available to you for free as downloads in the
Function
VRRP master
VRRP backup
09/2021
IP address
Subnet mask
192.168.1.2
255.255.255.0
192.168.1.3
255.255.255.0
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500Scalance s

Table of Contents