1
Enter Service mode, Service Information
How to enter to service mode.
Step1 :
D
[DIMMER] + [ON/STANDBY] x 2
M1.xx / xxxxxAEx
Step2 :
[SETUP] or [HOME]
1. Service
Step3:
C
Follow
this Tree
operation for each service mode.
Displaying Service information
This service information display system is helpful in analyze the status when the unit goes into
Protect mode and is powered off. Pay attention that the status will change if a button is pushed.
Follow
this Tree
for "ProtectData" section at the "1-1 Tech Sprt"
Step1 :
When the [ENTER] button is pressed, It will show error history
B
1
I 8 0 F 3 0 D D
History No.
PROTECT
: 1 ~ 3
I: Current Protect
(1 is latest.)
V: Voltage Protect
T: Thermal Protect
Step2:
When the [ENTER] button during display error history,
the additional information of error history will be appeared.
1
01: 23
A
Time after Power on
History No.
xx : xx
: 1 ~ 3
(1 is latest.)
1
2
The version of main microprocessor.
(displayed only for 3 seconds)
Tempe-
Volume
Listening Mode
rature
Value
See
This value
Information Displayed
10h
(Record this Information)
Cumulative operation time after Reset
: xx h
2
3
4
How to change History No. 1 ~ 3.
[CURSOR LEFT] or [CURSOR RIGHT]
1
I 8 0 F 3 0 D D
[CURSOR LEFT]
2
I 9 1 F 2 7 D D
3
- 0 0 F
T : 0
T : Thermal Protect
I : Current Protect
How to exit the service mode.
Please press the [ANY INPUT SELECTOR]
Normal display
How to clear Protect Data
Step1:
Select "ProtectDataCLR" from
Protect Data CLR
Step2:
Press [ENTER] button
After display "DATA Cleared!", It will be data reset and go to normal mode.
DataCleared!
3
4
5
Diagnostic Function
1
[CURSOR RIGHT]
[CUROR LEFT]
2
[ENTER]
0 0 A
3
I : 2
V : 0
Count of each protect
V : Voltage Protect
this tree
Clear:[ENTER]
5
6
01: 23
10h
D
[CURSOR RIGHT]
01: 47
8h
00: 00
00h
No Use
C
B
A
COMMON
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents