■ ■ ■ ■ ■ Initial Setting
1. Connect the AC adaptor.
2. Connect a Sustain pedal.
NOTE: If there is no Sustain pedal, Sustain pedal check can be skipped.
3. Connect to a PC through USB. (A USB driver must be installed on the PC.)
4. "MODE" switch: NORMAL
5. "Main" volume: MAX
■ ■ ■ ■ ■ How to start diagnostic program
1. While pressing down "+", "–", and "4" buttons at the same time, turn the power ON.
2. The massage "TST" is displayed on LCD.
3. Release "+", "–", and "4" buttons.
■ ■ ■ ■ ■ Diagnostic program
1. Button check
1 Press "0" button.
* Wait for confirmation sound.
2 Slide switches or press buttons in the order from No.01 to No.2D.
NOTE: The button numbers are written in hexadecimal numerals.
3 Press the "LAYER" button the last.
* Wait for confirmation sound.
* The Button number appears on the LCD.
* A buzzer sounds if buttons are pressed in a wrong order, and "CER" appears
on LCD.
NOTE: This check cannot be aborted in mid-course.
03
02
01
08
09
0A
0B
0C
2. AC adaptor check
1 Press "–" button.
3. Pedal check
1 Press "1" button.
2 "Sustain pedal": ON
3 "Sustain pedal": OFF

DIAGNOSTIC PROGRAM

04
05
06
07
0D 0E
0F
10
11
15
17
12
13
14
– 12 –
Message on LCD
00
BUTTON NO.
COK
BUTTON NO.
21
16
22
23
20
24
00
18
19
1A
1B
1C
1D
1E
1F
JOK
TCH
SUS
28
29
27
2A
26
2B
25
2C
2D
COK