4. SPK PCB
Proceeding :
TOP COVER
DIGITAL PCB →
(1) Remove the screws.
↑Shooting direction: A↑
(2) Remove the screws. Remove the CORD HOLDER and connectors. Remove the HOLDER.
CP4803
CP4002
CP4000
SPK PCB
x4
CP4803
CP4803
CP4001
x1
x5
PCB HOLDER
CORD HOLDER x4
5. TRANS
Proceeding :
TOP COVER
DIGITAL PCB →
(1) Remove the CORD HOLDERs and connector wires.
CP4607
(2) Remove the screws.
NOTE : It will separate and TRANS will fall from SET, if screws is removed.
6. SMPS PCB
Proceeding :
TOP COVER
→ SMPS PCB
See
"EXPLODED
VIEW" for instructions on removing the SMPS PCB.
7. REG PCB
Proceeding :
TOP COVER
REG PCB
See
"EXPLODED
VIEW" for instructions on removing the REG PCB.
8. AV PCB
Proceeding :
TOP COVER
DIGITAL PCB →
See
"EXPLODED
VIEW" for instructions on removing the AV PCB.
71
TRANS
from CP4401
CP4001
CP4142
CORD HOLDER x5
View from the bottom
x4
AV PCB