Download Print this page
Beurer BC 32 Manual

Beurer BC 32 Manual

Upper arm blood pressure monitor

Advertisement

Quick Links

Machine Translated by Google
Beurer BC 32 - Upper arm blood pressure monitor
Manual
Dear customers, thank you for choosing our products. Our name is synonymous with high quality, thoroughly tested products
for use in the areas of energy consumption, body temperature, heart rate, gentle manual therapy, massage and air therapy.
Please read this manual carefully and keep it for future reference, make sure that it is available to other users and follow the
instructions.
Sincerely, Your Beurer Team
1. Getting to know each other
The wrist blood pressure monitor is a non-invasive measure and control of the arterial blood pressure values of adults. With its
help, you can quickly and easily measure your blood pressure, save the measured values and have the course of the measured
values displayed. You will be warned if you have any heart rhythm problems.
The determined values are classified and graphically assessed according to WHO guidelines. Keep these operating
instructions for future reference and make them available to other users.
2. Important instructions
Instructions for use
• Always measure your blood pressure at the same time of day so that the values can be compared correctly.
• Rest for about 5 minutes before each measurement!
• You should wait 5 minutes between two measurements!
• The measured values can only be used for your information, they do not replace a medical examination! Discuss your values
with your doctor, never derive your own medical decisions (eg medicines and their dosage)!
• In the case of limited blood flow to the hand due to chronic or acute vascular diseases (including narrowing of blood
vessels), the accuracy of wrist measurements is limited. In this case, do not use a blood pressure monitor on your arm.
• Cardiovascular disease could cause erroneous measurements, even in very low blood pressure, circulatory and rhythm
disorders, and other previous conditions.
• Only use the device with a wrist circumference suitable for this device.
• You can only use the blood pressure monitor with batteries. Note that data storage is only possible if your blood pressure monitor
is powered. Once the batteries are exhausted, the date and time of the blood pressure monitor will be lost. However, the stored
measurement values are retained. Automatic shutdown turns off the blood pressure meter to save battery power if it is not within
one minute
some button pressed.
Storage and care instructions
• The blood pressure meter consists of precise and electronic components. The accuracy of the measured values and the service
life of the device depend on careful handling:
- Protect the device against shocks, moisture, dirt, strong temperature fluctuations and direct sunlight.
- Do not drop the device.
- Do not use the device near strong electromagnetic fields, keep it away from radio equipment or mobile phones.
• Do not press the buttons unless the cuff is attached.
• We recommend that you remove the batteries if you will not be using the device for a long time.
Battery instructions
• Batteries can be life-threatening if swallowed. Therefore, keep batteries and products out of the reach of small children. If the
battery is swallowed, you must call for medical help immediately.
• Batteries must not be charged or reactivated by other means, disassembled, thrown into a fire or shorted.
• Remove the batteries if they are exhausted or if you will not be using the device for a long time. This will prevent damage that
could occur after they have leaked. Always replace all batteries at the same time.
• Do not use different types, brands of batteries or batteries with different capacities. Preferably use alkaline batteries.
Repair and disposal instructions
• Batteries do not belong in the household waste. Please take the discharged batteries to the designated collection points.
• Do not open the device. Failure to do so will void the warranty.
• Do not repair or adjust the device yourself. In this case, perfect function is no longer ensured.
• Repairs may only be performed by customer service or authorized dealers. Before each complaint, first check the batteries
and replace them if necessary.
• Dispose of the device in accordance with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96 / EC. If you
have any questions, please contact the municipal disposal office.
Slovensky

Advertisement

loading

Summary of Contents for Beurer BC 32

  • Page 1 Machine Translated by Google Beurer BC 32 - Upper arm blood pressure monitor Slovensky Manual Dear customers, thank you for choosing our products. Our name is synonymous with high quality, thoroughly tested products for use in the areas of energy consumption, body temperature, heart rate, gentle manual therapy, massage and air therapy.
  • Page 2 Machine Translated by Google 3. Description of the device 1. Battery compartment cover 2. "MEM" save button 3. Function key "" 4. Adjustment button + 5. "START / STOP" button 6. Wrist cuff 7. Display Indication on the display 1. Battery replacement symbol 2.
  • Page 3 Machine Translated by Google In any case, make sure that the cuff is at heart level. Otherwise, significant deviations may occur. Release your arm and palms. • In order not to skew the measurement results, it is important that you are calm and do not speak during the measurement.
  • Page 4 • Do not place heavy objects on the device. 9. Technical parameters Model no. BC 32 Measurement method Oscillating, non-invasive measurement of blood pressure on the wrist Measuring range systolic 40 - 280 mmHg, diastolic 40 - 280 mmHg, pulse 40 - 199 beats / minute Pressure indication accuracy systolic ±...